MATERIAL NUMBER:
8BVI0055HWD0.000-1
DESCRIPTION:
- Integrated uncontrolled standstill and safe stop
- Integrated connection for motor holding brake and temperature sensor
- 2 slots for ACOPOSmulti plug-in modules
- Two fully independent power inverters in one inverter module contained in 2-axis modules
ACOPOSmulti inverter module, 7.6 A, AS, wall mounting, 2 axes
General information
B&R ID code | 0x20B5 |
Cooling and mounting type | Wall mounting |
Slots for plug-in modules | 2 |
Certifications | |
CE | Yes |
Functional safety | Yes |
UL | cULus E225616
Power conversion equipment |
EAC | Yes |
KC | Yes |
DC bus connection
Voltage | |
Nominal | 750 VDC |
Continuous power consumption | 11.19 kW |
Power dissipation depending on switching frequency | |
Switching frequency 5 kHz | [1.2 * IM² + 2.62 * IM + 100] W |
Switching frequency 10 kHz | [2.56 * IM² + 2.8 * IM + 200] W |
Switching frequency 20 kHz | [6 * IM² - 9.4 * IM + 430] W |
DC bus capacitance | 330 µF |
Variant | ACOPOSmulti backplane |
24 VDC power supply
Input voltage | 25 VDC ±1.6>#/td### |
Input capacitance | 23.5 µF |
Max. power consumption | 16 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake(s) |
Variant | ACOPOSmulti backplane |
24 VDC output
Quantity | 2 |
Output voltage | |
DC bus voltage (UDC): 260 to 315 VDC | 25 VDC * (UDC/315) |
DC bus voltage (UDC): 315 to 800 VDC | 24 VDC ±6>#/td### |
Fuse protection | 250 mA (slow-blow) electronic, automatic reset |
Motor connection
Quantity | 2 |
Continuous power per motor connection | 5.5 kW |
Continuous current per motor connection | 7.6 Aeff |
Reduction of continuous current depending on switching frequency | |
Switching frequency 5 kHz | No reduction |
Switching frequency 10 kHz | 0.22 A/K (starting at 43°C) |
Switching frequency 20 kHz | 0.15 A/K (starting at -14°C) |
Reduction of continuous current depending on installation elevation | |
Starting at 500 m above sea level | 0.76 Aeff per 1000 m |
Peak current per motor connection | 18.9 Aeff |
Nominal switching frequency | 5 kHz |
Possible switching frequencies | 5 / 10 / 20 kHz |
Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
Protective measures | |
Overload protection | Yes |
Short-circuit and ground fault protection | Yes |
Max. output frequency | 598 Hz |
Variant | |
U, V, W, PE | Connector |
Shield connection | Yes |
Terminal connection cross section | |
Flexible and fine-stranded wires | |
With wire end sleeves | 0.25 to 6 mm² |
Approbation data | |
UL/C-UL-US | 30 to 10 AWG |
CSA | 28 to 10 AWG |
Terminal cable cross section dimension of shield connection | 12 to 22 mm |
Max. motor line length depending on switching frequency | |
Switching frequency 5 kHz | 25 m |
Switching frequency 10 kHz | 25 m |
Switching frequency 20 kHz | 10 m |
Motor holding brake connection
Quantity | 2 |
Output voltage | 24 VDC +5.8% / -0% |
Continuous current per connection | 1.1 A |
Max. internal resistance | 0.5 Ω |
Extinction potential | Approx. 30 V |
Max. extinction energy per switching operation | 1.5 Ws |
Max. switching frequency | 0.5 Hz |
Protective measures | |
Overload and short-circuit protection | Yes |
Open-circuit monitoring | Yes |
Undervoltage monitoring | Yes |
Response threshold for open-circuit monitoring | Approx. 0.25 A |
Response threshold for undervoltage monitoring | 24 VDC +0% / -4>#/td### |
Enable inputs
Quantity | 4 (2 per axis) |
Circuit | Sink |
Electrical isolation | |
Input - Inverter module | Yes |
Input - Input | Yes |
Input voltage | |
Nominal | 24 VDC |
Maximum | 30 VDC |
Input current at nominal voltage | Approx. 30 mA |
Switching threshold | |
Low | <5 V |
High | >15 V |
Switching delay at nominal input voltage | |
Enable 1 → 0, PWM off | Max. 20.5 ms |
Enable 0 → 1, ready for PWM | Max. 100 µs |
Modulation compared to ground potential | Max. ±38 V |
OSSD signal connections | Permitted
Max. test pulse length: 500 µs |
Trigger inputs
Quantity | 2 |
Circuit | Sink |
Electrical isolation | |
Input - Inverter module | Yes |
Input - Input | Yes |
Input voltage | |
Nominal | 24 VDC |
Maximum | 30 VDC |
Switching threshold | |
Low | <5 V |
High | >15 V |
Input current at nominal voltage | Approx. 10 mA |
Switching delay | |
Rising edge | 52 µs ±0.5 µs (digitally filtered) |
Falling edge | 53 µs ±0.5 µs (digitally filtered) |
Modulation compared to ground potential | Max. ±38 V |
Electrical properties
Discharge capacitance | 0.2 µF |
Operating conditions
Permissible mounting orientations | |
Hanging vertically | Yes |
Horizontal, face up | Yes |
Standing horizontally | No |
Installation elevation above sea level | |
Nominal | 0 to 500 m |
Maximum | 4000 m |
Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
Overvoltage category per EN 61800-5-1 | III |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | |
Nominal | 5 to 40°C |
Maximum | 55°C |
Storage | -25 to 55°C |
Transport | -25 to 70°C |
Relative humidity | |
Operation | 5 to 85>#/td### |
Storage | 5 to 95>#/td### |
Transport | Max. 95% at 40°C |
Mechanical properties
Dimensions | |
Width | 53 mm |
Height | 317 mm |
Depth | |
Wall mounting | 263 mm |
Weight | Approx. 2.9 kg |
Module width | 1 |