Please sign in so that we can notify you about a reply
Description
X20 DO F322 | X20DOF322
- 16 digital outputs
- Source connection
- 1-wire connections
- Integrated output protection
The module is equipped with 16 outputs for 1-wire connections. The module is designed for source output wiring.
| |
B&R ID code | 0xC0EA |
Status indicators | I/O function per channel, operating state, module status |
Diagnostics | |
Module run/error | Yes, using LED status indicator and software |
Outputs | Yes, using LED status indicator and software (output error status) |
Power consumption | |
Bus | 0.28 W |
Internal I/O | 0.95 W |
Additional power dissipation caused by actuators (resistive) [W] | +0.56 W |
Digital outputs
Variant | Current-sourcing FET |
Nominal voltage | 24 VDC |
Switching voltage | 24 VDC -15% / +20>#/td### |
Nominal output current | 0.5 A |
Total nominal current | 8 A |
Connection type | 1-wire connections |
Output circuit | Source |
Output protection | Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current") Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads") |
Diagnostic status | Output monitoring with 10 ms delay |
Leakage current when the output is switched off | 5 µA |
RDS(on) | 140 mΩ |
Peak short-circuit current | <3 A |
Switch-on in the event of overload shutdown or short-circuit shutdown | Approx. 10 ms (depends on the module temperature) |
Switching delay | |
0 → 1 | <300 µs |
1 → 0 | <300 µs |
Switching frequency | |
Resistive load | Max. 500 Hz |
Inductive load | See section "Switching inductive loads". |
Braking voltage when switching off inductive loads | Typ. 45 VDC |
Insulation voltage between channel and bus | 500 Veff |
Electrical properties
Electrical isolation | Channel isolated from bus Channel not isolated from channel and I/O power supply |
Operating conditions
Mounting orientation | |
Horizontal | Yes |
Vertical | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | -25 to 60°C |
Vertical mounting orientation | -25 to 50°C |
Derating | See section "Derating". |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Mechanical properties
Note | Order 1x terminal block X20TB1F separately. Order 1x bus module X20BM11 separately. |
Pitch | 12.5+0.2mm |
MANUFACTURERS
Price history