B&R Automation X20SI9100 20 safe type A digital inputs, 4 pulse outputs, 24 VDC

Brand:B&R AUTOMATION, Condition:new
$0.00

Order today and receive in 4 weeks (pay when ready):

$0.00

X20SI9100
PREORDER
+

Description

  • 20 safe digital inputs
  • 4 pulse outputs
  • Sink circuit
  • Software input filter configurable for each channel

This module is equipped with 20 safe digital inputs. It is designed for a nominal voltage of 24 VDC.

The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3.

The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.

This module is designed for X20 12-pin terminal blocks.


I/O module20 safe type A digital inputs, 4 pulse outputs, 24 VDC
General information
B&R ID code0xAEC8
System requirements
Automation Studio3.0.81.15 or later
Automation Runtime3.00 or later
SafeDESIGNER2.71 or later
Safety Release1.3 or later
mapp Technology Package mapp Safety 5.7.0 or later
Status indicatorsI/O function per channel, operating state, module status
Diagnostics
Module run/errorYes, using LED status indicator and software
InputsYes, using LED status indicator and software
Blackout mode
ScopeModule
FunctionModule functionality
Standalone modeNo
Max. I/O cycle time1600 µs
Power consumption
Bus0.4 W
Internal I/O1.6 W
Additional power dissipation caused by actuators (resistive) [W] 0.6
Electrical isolation
Channel - BusYes
Channel - ChannelNo
Certifications
CEYes
Functional safetycULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013
Functional safetyIEC 61508:2010, SIL 3 EN 62061:2013, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3
Functional safetyEN 50156-1:2004
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: A(0 - 45°C) Humidity: B(up to 100%) Vibration: A(0.7 g) EMC: B(bridge and open deck)
LRENV1
KRYes
ABSYes
EACYes
KCYes
Safety characteristics
EN ISO 13849-1:2015
CategoryCat. 3 when using individual input channels, Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels 
PLPL e
DC>94>#/td###
MTTFD2500 years
Mission timeMax. 20 years
IEC 61508:2010, IEC 61511:2004, EN 62061:2013
SIL CLSIL 3
SFF>90>#/td###
PFH / PFHd
Module<1*10-10
openSAFETY wiredNegligible
openSAFETY wireless<1*10-14* Number of openSAFETY packets per hour
PFD<2*10-5
Proof test interval (PT)20 years
I/O power supply
Nominal voltage24 VDC
Voltage range24 VDC -15% / +20>#/td###
Integrated protectionReverse polarity protection
Safe digital inputs
Quantity20
VariantType A
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input filter
Hardware≤150 μs
SoftwareConfigurable between 0 and 500 ms
Input circuitSink
Input voltage24 VDC -15% / +20>#/td###
Input current at 24 VDC Min. 2 mA to max. 3.28 mA
Input resistanceMin. 7.33 kΩ
Error detection time200 ms
Insulation voltage between channel and bus500 Veff
Switching threshold
Low<5 VDC
High>15 VDC
Line length between signal source (pulse output or external signal) and inputMax. 60 m with unshielded line Max. 400 m with shielded line
Pulse outputs
Quantity4
VariantPush-Pull
Nominal output current50 mA
Output protectionShutdown of individual channels in the event of overload or short circuit 
Peak short-circuit current25 A for 5 ms, hardware revision D0 and later: 25 A for 15 µs
Short-circuit current100 mAeff
Leakage current when the output is switched off0.1 mA
RDS(on)60 Ω
Switching voltageI/O power supply minus voltage drop due to RDS(on)
Total nominal current200 mA
Operating conditions
Mounting orientation
HorizontalYes
VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation0 to 60°C
Vertical mounting orientation0 to 50°C
DeratingSee section "Derating".
Storage-40 to 85°C
Transport-40 to 85°C
Relative humidity
Operation5 to 95%, non-condensing
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 2x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately.
Pitch25+0.2mm