B&R Automation X20SL8100 Powerlink module

$3,724.00
X20SL8100
Out of stock
+
  • openSAFETY manager for up to 100 SafeNODEs
  • Flexibly programmable using Automation Studio / SafeDESIGNER
  • Innovative management of safe machine options (SafeOPTION)
  • Parameter and configuration management

The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3.

In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.

Short description
InterfacesPOWERLINK
System moduleCPU
General information
B&R ID code0xDD61
System requirements
Automation Studio4.0.16 or later
Automation RuntimeV3.08 or later (for AsSafety library F4.06 or later)
SafeDESIGNER3.1.0 or later
Safety Release1.7 or later
mapp Technology Package mapp Safety 5.7.0 or later
CoolingFanless
Status indicatorsCPU function, POWERLINK, SafeKEY
Diagnostics
CPU functionYes, using LED status indicator
POWERLINKYes, using LED status indicator
SafeKEYYes, using LED status indicator
Support
Dynamic node allocation (DNA)Yes
Power consumption4.3 W
Additional power dissipation caused by actuators (resistive) [W]-
Certifications
CEYes
UKCAYes
Functional safetycULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013
Functional safetyIEC 61508:2010, SIL 3 EN 62061:2005/A2:2015, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3
Functional safetyEN 50156-1:2004
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: A(0 - 45°C) Humidity: B(up to 100%) Vibration: A(0.7 g) EMC: B(bridge and open deck)
LRENV1
KRYes
ABSYes
BVEC21B Temperature: 5 - 45°C Vibration: 0.7 g EMC: Bridge and open deck
EACYes
Safety characteristics
EN ISO 13849-1:2015
CategoryCat. 4
PLPL e
DC>94>#/td###
MTTFD per channel2500 years
Mission timeMax. 20 years
IEC 61508:2010, IEC 61511:2004, EN 62061:2013
SIL CLSIL 3
SFF>90>#/td###
PFH / PFHd per channel<1*10-10
PFH / PFHd
openSAFETY wiredNegligible
openSAFETY wireless<1*10-14* Number of openSAFETY packets per hour
PFD per channel<2*10-5
Proof test interval (PT)20 years
Functionality
Communication with each otherYes
Support for Safe Commissioning Options
BOOL512
INT64
UINT64
DINT64
UDINT64
SafeMOTION supportYes, depends on the number of available operating licenses on the SafeKEY
Max. number of SafeMOTION axes70, depends on the data width of the modules used
Timing precisionTime * 0.05 + Cycle time of the safety application
Shortest task class cycle time1 ms
Max. number of SafeNODEs100, depends on the number of available operating licenses on the SafeKEY
Max. number of POWERLINK controlled nodes50
Data exchange between CPU and SafeLOGIC controller 
Max. total data width for each direction 512 bytes
Max. number of data points for each direction
BOOL1024
INT128
UINT128
DINT64
UDINT64
Data exchange between SafeDOMAIN and SafeDOMAIN 
Use as Managing SafeDOMAINYes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0
Use as Connected SafeDOMAINYes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0
Max. total data width for each direction 64 bytes
Max. total number of data points for each direction 16
Max. number of data points for each direction
BOOL128
INT16
UINT16
DINT16
UDINT16
Max. number of linked Managing SafeDOMAINsStarting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0: 10
Limit values for SafeDESIGNER application
Max. resources available for SafeDESIGNER info window entries 
FB instances4096
Marker memory262,144 bytes
Stack memory32,768 bytes
Memory for safe input data6144 bytes
Memory for safe output data2048 bytes
Memory for standard input data1024 bytes
Memory for standard output data1024 bytes
Marker count16,382
Additional SafeDESIGNER limit values
Max. number of function block types512
Max. number of force variables64
Max. number of variable with variable status1023
Input SL / BC / X2X Link power supply
Input voltage24 VDC -15% / +20>#/td###
Input currentMax. 0.25 A
Fuse-
Reverse polarity protectionYes
Interfaces
FieldbusPOWERLINK controlled node
Variant2x shielded RJ45 port (hub)
Line lengthMax. 100 m between 2 nodes (segment length)
Transfer rate100 Mbit/s
Transfer
Physical layer100BASE-TX
Half-duplexYes
Full-duplexNo
AutonegotiationYes
Auto-MDI/MDIXYes
Min. cycle time 
Fieldbus200 µs
Operating conditions
Mounting orientation
HorizontalYes
VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation0 to 60°C
Vertical mounting orientation0 to 45°C
Derating-
Storage-40 to 85°C
Transport-40 to 85°C
Relative humidity
Operation5 to 95%, non-condensing
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder SafeKEY and SafeLOGIC range of functions using the X20MK configurator. X20 end cover plate (right) included in delivery 12-pin X20 terminal block, safety-keyed, included in delivery SafeKEY cover included in delivery
Dimensions
Width62.5+0.2mm
Height99 mm
Depth75 mm
Weight190 g
Brands:
B&R AUTOMATION
Condition:
new

Price history Price history