B&R Automation X20SO4110 4 safe type A digital outputs, with current monitoring, 24 VDC, 0.5 A, OSSD <500 µs

$1,150.00
X20SO4110
Out of stock
+
DESCRIPTION:
  • 4 safe digital outputs with 0.5 A
  • Source circuit
  • Output type A
  • Current monitoring
  • Open circuit detection
  • Integrated output protection

This module is equipped with 4 safe digital outputs. The nominal output current is 0.5 A.

The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3.

The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side low-side" variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. Safe digital output channels provide protection against automatic restart when network errors occur and also using a current measurement for open circuit detection.

This module is designed for X20 12-pin terminal blocks.

General information
B&R ID code0x1DBE
System requirements
Automation Studio3.0.71 or later
Automation Runtime2.95 or later
SafeDESIGNER2.58 or later
Safety Release1.1 or later
mapp Technology Package mapp Safety 5.7.0 or later
Status indicatorsI/O function per channel, operating state, module status
Diagnostics
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software
Blackout mode
ScopeModule
FunctionModule functionality
Standalone modeNo
Max. I/O cycle time800 µs
Power consumption
Bus0.25 W
Internal I/O1.3 W
Additional power dissipation caused by actuators (resistive) [W] 0.24
Electrical isolation
Channel - BusYes
Channel - ChannelNo
Certifications
CEYes
UKCAYes
Functional safetycULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013
Functional safetyIEC 61508:2010, SIL 3 EN 62061:2005/A2:2015, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3
Functional safetyEN 50156-1:2004
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: A(0 - 45°C) Humidity: B(up to 100%) Vibration: A(0.7 g) EMC: B(bridge and open deck)
LRENV1
KRYes
ABSYes
BVEC21B Temperature: 5 - 45°C Vibration: 0.7 g EMC: Bridge and open deck
EACYes
KCYes
Safety characteristics
I/O power supply
Nominal voltage24 VDC
Voltage range24 VDC -15% / +20>#/td###
Integrated protectionReverse polarity protection
Safe digital outputs
Quantity4
VariantFET, 1x positive switching, 1x negative switching, type A, output level readable, open-circuit detection
Nominal voltage24 VDC
Nominal output current0.5 A
Total nominal current2 A
Output protectionSee section "Inrush current behavior for output channels".
Braking voltage when switching off inductive loadsMax. 90 VDC 
Open-circuit detectionVia internal current measurement, output current <10 mA: Signal "CurrentOK" = FALSE, output current 10 to 50 mA: Signal "CurrentOK" = Undefined, output current >50 mA: Signal "CurrentOK" = TRUE
Error detection time1 s
Insulation voltage between channel and bus500 Veff
Peak short-circuit currentSee section "Inrush current behavior for output channels".
Leakage current when the output is switched off<10 µA
RDS(on)240 mΩ
Switching voltageI/O power supply minus voltage drop due to RDS(on)
Max. switching frequencySee section "Inrush current behavior for output channels".
Test pulse lengthMax. 500 µs
Time between two test pulsesMin. 49.5 ms
Max. capacitive load100 nF
Operating conditions
Mounting orientation
HorizontalYes
VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation0 to 60°C
Vertical mounting orientation0 to 50°C
DeratingSee section "Derating".
Storage-40 to 85°C
Transport-40 to 85°C
Relative humidity
Operation5 to 95%, non-condensing
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately.
Pitch25+0.2mm


Brands:
B&R AUTOMATION
Condition:
new

Price history Price history