Description
Interfaces | 1x RS232 service interface |
General information
B&R ID code | 0x1F8C |
Status indicators | Overload, operating status, module status, RS232 |
Diagnostics | |
Module run/error | Yes, using LED status indicator and software |
RS232 data transfer | Yes, using LED status indicator |
Overload | Yes, using LED status indicator and software |
Power consumption for X2X Link power supply | 1.42 W |
Power consumption | |
Internal I/O | 0.6 W |
Additional power dissipation caused by actuators (resistive) [W] | - |
Certifications | |
CE | Yes |
UKCA | Yes |
ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
UL | cULus E115267 Industrial control equipment |
HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
DNV | Temperature: B(0 - 55°C) Humidity: B(up to 100%) Vibration: B(4 g) EMC: B(bridge and open deck) |
LR | ENV1 |
KR | Yes |
ABS | Yes |
BV | EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
EAC | Yes |
KC | Yes |
Bus controller / X2X Link power supply input
Input voltage | 24 VDC -15% / +20>#/td### |
Input current | Max. 0.7 A |
Fuse | Integrated, cannot be replaced |
Reverse polarity protection | Yes |
Bus controller / X2X Link power supply output
Nominal output power | 7 W |
Parallel connection | Yes |
Redundant operation | Yes |
Overload characteristics | Short-circuit proof, temporary overload |
Input I/O power supply
Input voltage | 24 VDC -15% / +20>#/td### |
Fuse | Required line fuse: Max. 10 A, slow-blow |
Reverse polarity protection | No |
Output I/O power supply
Nominal output voltage | 24 VDC |
Behavior on short circuit | Required line fuse |
Permissible contact load | 10 A |
Interfaces
Service interface | |
Signal | RS232 |
Variant | Connection made using 12-pin terminal block X20TB12 |
Max. transfer rate | 115.2 kbit/s |
Electrical properties
Electrical isolation | BC/X2X Link supply isolated from BC/X2X Link power supply I/O supply not isolated from I/O power supply, and RS232 not isolated from bus |
Operating conditions
Mounting orientation | |
Horizontal | Yes |
Vertical | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | -25 to 60°C |
Vertical mounting orientation | -25 to 50°C |
Derating | See section "Derating". |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Mechanical properties
Note | Order 1x terminal block X20TB12 separately. Order 1x bus base X20BB8x separately. |
Pitch | 12.5+0.2mm |
MANUFACTURERS
Price history
As soon as the price of the products decreases, you will immediately know about it.
The price has not changed yet. We will show it on this chart once it changes