Euchner TP3-4131A024M | 084129 Safety switch TP with door monitoring contact

$225.00

Order today and receive in 4 weeks (pay when ready):

$0.00

TP3-4131A024M
PREORDER
+

Description

  • Auxiliary release on the front
  • With door monitoring contact
  • Increased horizontal overtravel

Approach direction



Horizontal and vertical

Can be adjusted in 90° steps

Increased overtravel for horizontal approach direction

Solenoid operating voltage

  • AC/DC 24 V 10%, -15>#/li###

Guard locking type

TP3

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

Switching element

4131

Slow-action contact 2 Ö  1 S 1 S (door monitoring contact)

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_2/1CCC_2020980305000541_CQC2008010305306207DGUV_ET 20002_ET 20003

Electrical connection values

Power consumption8 W
Connection cross section0.34 ... 1.5 mm²
Rated insulation voltage Ui250 V
Rated impulse withstand voltage Uimp2.5 kV
Utilization category
AC-154A 230V
DC-134A 24V
Solenoid operating voltage
AC/DC24 V -15% ... +10>#/td###
Solenoid duty cycle100 >#/td###
Switching voltage
min. at 10 mA12 V
Switching current
min. at 24 V1 mA

Mechanical values and environment

Approach speedmax. 20 m/min
Connection type
3 xM20 x 1.5
Number of door position NO contacts1
Number of guard lock monitoring NO contacts1
Number of guard lock monitoring positively driven contacts2
Extraction force20 N
Actuation frequencymax. 1200 1/h
Actuating force10 N
Installation orientationany
Mechanical life1 x 10⁶
Retention force10 N
Switching principleSlow-action switching contact
Degree of protectionIP67
Ambient temperature-20 ... +55 °C
Material
HousingReinforced thermoplastic
ContactSilver alloy, gold flashed
Locking force Fmax1300 N
Locking force FZh1000 N
Guard locking principleClosed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Control of guard locking
CategoryDepending on external control of guard locking
Performance LevelDepending on external control of guard locking
PFHDDepending on external control of guard locking
Monitoring of guard locking and the guard position
B10D3 x 10⁶

In combination with actuator ACTUATOR-P-GT

Horizontal overtravel2 mm
Vertical overtravel1.5 mm

In combination with actuator ACTUATOR-P-GNT

Horizontal overtravel7 mm