Description
Model | GT2-H12K | |
Detection method | Scale Shot System Absolute (No Value Jump) Type | |
Measurement range | 12 mm | |
resolution | 0.1 µm | |
Instruction accuracy | 1 µm (PP) * 1 | |
Measuring power | When installed facing down | 1.0 N * 2 |
When installed sideways | 0.9 N * 2 | |
When installed facing up | 0.8 N * 2 | |
Sampling cycle | 1 ms | |
Mechanical responsiveness | 10 Hz * 3 | |
Operation indicator | 2-color LED (red, green) | |
Environmental resistance | Protection class | IP67 (IEC) |
Operating ambient temperature | -10 to + 55 ° C (do not freeze) | |
Operating ambient humidity | 35-85% RH (no condensation) | |
Vibration resistant | 10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction | |
Impact resistance | 1,000 m / s 2 (IEC60068-2-27) | |
Material | Body | Body case: Zinc die-cast, indicator light: Polyarylate (PAR) |
Dust boots | NBR | |
Contact | SUS304, Cemented Carbide Tungsten Alloy * 4 | |
Head cable | Sold separately (connected to M8 connector) | |
mass | Approximately 95 g (cable not included) | |
* 1 Value for the entire measurement range and ambient temperature of 20 ° C. * 2 This is a representative value near the measurement center value. Please note that the measuring force changes depending on the mounting condition of the dust boots. * 3 Value when the ambient temperature is 20 ° C. * 4 Contact is also available as an option sold separately. |