Description
100 to 240 VAC, Preset Counter, 1 step, 48 mm x 48 mm, 6 digit, No-voltage/Voltage input selectable=>No-voltage (NPN)/Voltage input (PNP) selectable, Increment decrement or increment/decrement, command/individual/quadrature input, S080?Contact output, Memory backup
Rated supply voltage | 100 to 240 VAC 50/60 Hz |
---|---|
Preset stages | 1 step |
Digits | 6 digit |
External connection method | Screw terminal |
Mounting method | Flush mounting |
Function | 1 Stage Preset Counter, Total Preset Counter | |
---|---|---|
Preset stages | 1 step | |
Rated supply voltage | 100 to 240 VAC 50/60 Hz | |
Operating voltage range | 85 to 110% of the power supply voltage | |
Power consumption | AC: Approx. 9.4 VA (at 100 to 240 VAC) | |
External power supply | 12 VDC (±10%) 100 mA | |
Counter | Count range | -99999 to 999999 |
Max. counting speed | 30 Hz/10 kHz (switching) | |
Minimum input signal width | 30 Hz: 16.7 ms 10 kHz: 0.05 ms | |
Input mode | Increment decrement or increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual input) and UP/DOWN C(quadrature input)) | |
Output modes | N, F, C, R, K-1, P, Q, A, K-2, D, L | |
One-shot output time | 0.01 to 99.99 s variable | |
Reset system | External, manual and automatic reset (internal according to C, R, P and Q mode operation) | |
Input | Input signal | CP1, CP2, Reset, Total reset |
Input method | No-voltage (NPN)/Voltage input (PNP) selectable | |
No-voltage input (No-contact input) | Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA) Residual voltage: 3 V max. Open circuit impedance: 100 kΩ min. | |
No-voltage input (Contact input) | Use a contact which can adequately switch 5 mA at 10 V. | |
Voltage input | Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΩ) | |
Contact input | Use a contact which can adequately switch 5 mA at 10 V. | |
Reset time | External reset | 1 ms/20 ms (selectable) |
Control output | Contact output | Contact form: SPDT Switching capacities: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) |
Display | Display method | 7-segment negative transmissive LCD |
Digits | 6 digit | |
Character height | Count value: 10 mm (Red, green or orange programmable) Set value: 6 mm (green) | |
Prescaling function | 0.001 to 99.999 | |
Decimal point adjustment | Rightmost 3 digits | |
Key protection | Key protect Switch | |
Memory backup methods | Method: EEP-ROM, Number of rewite: 100,000 operations min., Service life: 10 years min. | |
Ambient temperature (Operating) | -10 to 55 ℃ (with no freezing or condensation) Close mounting: -10 to 50 ℃ (with no freezing or condensation) | |
Ambient temperature (Storage) | -25 to 70 ℃ (with no freezing or condensation) | |
Ambient humidity (Operating) | 25 to 85% RH | |
Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC) | |
Dielectric withstand voltage | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and input circuit: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min | |
Impulse withstand voltage | Between power terminals: 3 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV | |
Noise immunity | Between power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) | |
Static immunity | Mulfunction: 8 kV, Destruction: 15 kV | |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min | |
Shock resistance | Destruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 3 axes each directions | |
Life expectancy | Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, 23 ℃) Mechanical: 10 million operations min. | |
Degree of protection | Case front: IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing) | |
External connection method | Screw terminal | |
Case color | Black (Munsell N1.5) | |
Accessories | Flush mounting adapter, Waterproof packing, Terminal Cover | |
Weight | Approx. 130 g |
Features
EAN:
4536854124570
Condition:
NEW
MANUFACTURERS
Price history
As soon as the price of the products decreases, you will immediately know about it.