Description
- For applications in hazardous areas
- Reliable non-contact monitoring of the rotational speed with regard to underspeed
- 2 in 1: speed sensor and evaluation in one compact housing
- Easy setting of the switch point via potentiometer
- For direct connection to a PLC
Output function | normally open |
---|---|
Sensing range [mm] | 10 |
Dimensions [mm] | M30 x 1.5 / L = 80 |
Application
Application | simple evaluation of rotating and linear movement with regard to underspeed; blocking |
---|
Electrical data
Nominal voltage AC [V] | 20...250 |
---|---|
Nominal voltage DC [V] | 20...250 |
Nominal frequency AC [Hz] | 45...65 |
Protection class | II |
Reverse polarity protection | yes |
Outputs
Total number of outputs | 1 |
---|---|
Output function | normally open |
Max. voltage drop switching output DC [V] | 7.5 |
Minimum load current [mA] | 6 |
Max. leakage current [mA] | 1.5 |
Permanent current rating of switching output AC [mA] | 200 |
Permanent current rating of switching output DC [mA] | 100 |
Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) |
Short-circuit proof | no |
Overload protection | no |
Detection zone
Sensing range [mm] | 10 |
---|---|
Sensing range adjustable | no |
Real sensing range Sr [mm] | 10 ± 10 >#/td### |
Operating distance [mm] | 0...8.1 |
Measuring/setting range
Setting range [Imp/min] | 5...3600 |
---|
Accuracy / deviations
Correction factor | steel: 1 / stainless steel: 0.8 / brass: 0.5 / aluminium: 0.5 / copper: 0.4 |
---|---|
Hysteresis [% of Sr] | 10 |
Response times
Start-up delay [s] | 12 |
---|---|
Max. damping frequency [Imp/min] | 4800 |
Software / programming
Adjustment of the switch point | multiturn potentiometer |
---|
Operating conditions
Ambient temperature [°C] | -20...60 |
---|---|
Storage temperature [°C] | -25...60 |
Protection | IP 65; IP 67 |
Tests / approvals
Approval | IECEx BVS 17.0094X | ||
---|---|---|---|
ATEX marking | |||
EMC |
| ||
MTTF [years] | 491 |
Mechanical data
Weight [g] | 314 |
---|---|
Mounting | flush mountable |
Dimensions [mm] | M30 x 1.5 / L = 80 |
Thread designation | M30 x 1.5 |
Materials | brass special coating; PA; TPE-U |
Displays / operating elements
Display |
|
---|
Electrical connection
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
---|
Accessories
Items supplied |
|
---|
Remarks
Remarks |
|
---|
Electrical connection
Connection | Cable: 2 m, PUR; 2 x 0.5 mm² |
---|
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — EN-GB — DI103A — 24.04.2023 —
Features
Production:
OLD STOCK
Condition:
Condition:NEW
MANUFACTURERS
Price history
As soon as the price of the products decreases, you will immediately know about it.
The price has not changed yet. We will show it on this chart once it changes