Free shipping

IFM O1D100 O1DLF3KG Photoelectric distance sensor

Brand:IFM, Condition:new
$398.00

Order today and receive in 4 weeks (pay when ready):

$0.00

O1D100 O1DLF3KG
PREORDER
+

Description

  • Reliable optical distance measurement with long ranges up to 10 m
  • Two switching outputs, one of them programmable as analog output
  • Scalable measuring range and window function
  • Use in applications with background suppression
  • Excellent price/performance ratio


Product characteristics
Laser protection class2
Housingrectangular
Electrical data
Operating voltage [V]18...30 DC; (cULus - Class 2 source required)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Typ. lifetime [h]50000
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs2
Electrical designPNP
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Max. current load per output [mA]200
Number of analog outputs1
Analog current output [mA]4...20; (IEC 61131-2)
Max. load [Ω]250
Analog voltage output [V]0...10; (IEC 61131-2)
Min. load resistance [Ω]5000
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Monitoring range
Max. light spot width [mm]15
Max. light spot height [mm]15
Light spot dimensions refer to10 m
Background suppression [m]0...19
Measuring/setting range
Measuring range [m]0.2...10; (white paper 200 x 200 mm 90 % remission)
Sampling rate [Hz]1...50
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO modeyes
Required master port classA
Process data analog2
Process data binary3
Min. process cycle time [ms]6
Supported DeviceIDs
Type of operationDeviceID
default806
Operating conditions
Ambient temperature [°C]-10...60
ProtectionIP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class2
Notes on laser protection
Caution:Laser light
Power:<= 4 mW
Wave length:650 nm
pulse:1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class:2
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years]182
Mechanical data
Weight [g]303
Housingrectangular
Dimensions [mm]59 x 42 x 52
Materialhousing: diecast zinc; front lens: glass; LED window: PC
Lens alignmentSide sensing
Displays / operating elements
Display
Switching status2 x LED, yellow
PowerLED, green
Distance, programmingalphanumeric display, 4-digit
Accessories
Accessories (optional)
Protective cover, E21133
Remarks
Remarks
For more information about the measuring range / application please refer to the operating instructions.
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12
Other data
ParameterSetting rangeFactory setting
Unimm, m, inchmm
OU1Hno, Hnc, Fno, FncHno
SP1 [mm]200...99991000
nSP1 [mm]200...9999800
FSP1 [mm]200...99991200
OU2Hno, Hnc, Fno, Fnc, I, UI
SP2 [mm]200...99992000
nSP2 [mm]200...99991800
FSP2 [mm]200...99992200
ASP [mm]0...99990
AEP [mm]0...99999999
rATE [Hz]1...5050
dS1 [s]0...0.1...50
dr1 [s]0...0.1...50
dS2 [s]0...0.1...50
dr2 [s]0...0.1...50
dFo [s]0...0.1...50
dISd1...3 ; rd1...3; OFFd3
Repeatability / Accuracy
read/write distance (mm)Repeatability of the measured valuesAccuracy
white (90 % remission)grey (18 % remission)white (90 % remission)grey (18 % remission)
200...1000 mm± 5.0 mm±7.5 mm± 15.0 mm± 18.0 mm
1000...2000 mm± 5.5 mm±10.0 mm± 15.0 mm± 20.0 mm
2000...4000 mm± 17.5 mm±22.5 mm± 25.0 mm± 32.0 mm
4000...6000 mm± 27.5 mm±40.0 mm± 35.0 mm± 50.0 mm
6000...10000 mm± 60.0 mm± 70.0mm
Sampling rate50 Hz
Extraneous light on the object< 40 klx
Repeatability / Accuracy
read/write distance (mm)Repeatability of the measured valuesAccuracy
white (90 % remission)grey (18 % remission)white (90 % remission)grey (18 % remission)
200...1000 mm± 16.5 mm±16.5 mm± 26.5 mm± 26.5 mm
1000...2000 mm± 16.5 mm±16.5 mm± 26.5 mm± 26.5 mm
2000...4000 mm± 30.0 mm±37.0 mm± 40.0 mm± 47.0 mm
4000...6000 mm± 37.0 mm±57.0 mm± 47.0 mm± 67.0 mm
6000...10000 mm± 75.0 mm± 85.0mm
Sampling rate50 Hz
Extraneous light on the object40...100 klx
Repeatability / Accuracy
read/write distance (mm)Repeatability of the measured valuesAccuracy
white (90 % remission)grey (18 % remission)white (90 % remission)grey (18 % remission)
200...1000 mm± 4.0 mm±4.5 mm± 14.0 mm± 15.0 mm
1000...2000 mm± 4.5 mm±6.0 mm± 14.5 mm± 16.0 mm
2000...4000 mm± 13.5 mm±14.5 mm± 23.5 mm± 24.0 mm
4000...6000 mm± 19.0 mm±21.0 mm± 29.0 mm± 31.0 mm
6000...10000 mm± 37.0 mm± 47.0mm
Sampling rate1 Hz
Extraneous light on the object< 40 klx
Repeatability / Accuracy
read/write distance (mm)Repeatability of the measured valuesAccuracy
white (90 % remission)grey (18 % remission)white (90 % remission)grey (18 % remission)
200...1000 mm± 10.0 mm± 10.0 mm± 20.0 mm± 20.0 mm
1000...2000 mm± 10.0 mm± 10.0 mm± 20.0 mm± 20.0 mm
2000...4000 mm± 17.0 mm± 18.0 mm± 27.0 mm± 28.0 mm
4000...6000 mm± 22.0 mm± 25.0 mm± 32.0 mm± 35.0 mm
6000...10000 mm± 37.0 mm± 47.0mm
Sampling rate1 Hz
Extraneous light on the object< 40...100 klx
--
Range on black object (6 % remission)<= 4000 mm
--
>td >
constant ambient conditions23 °C / 960 hPa
minimum power-on time in minutes10
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — O1D100-06 — 18.01.2011 — 