Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB) - high-speed type - Mitsubishi (UL 489 Listed ELCBs (harmonic surge ready) - NF-S (standard class)) - 3-poles (3P) - Rated current 5A - Residual current sensitivity 30mA - Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947) - Short circuit current rating 14kA (240Vac; UL489) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection connection
Specifications
Primary brand
Mitsubishi
Main function
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / ELCB
Product series / family name
UL 489 Listed ELCBs (harmonic surge ready)
Sub-range name
NF-S (standard class)
Functions
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB)
Design
high-speed type
Poles
3-poles (3P)
Rated current
5A
Frame current rating
50 AF
Residual current sensitivity
30mA
Rated voltage (AC)
120-240Vac (UL 489)
Connection type
Front lugs or bars connection
Short circuit breaking rating
14kA (120Vac; UL489)
14kA (240Vac; UL489)
Ultimate short circuit current breaking capacity (Icu)
15kA (100Vac; IEC60947)
15kA (230Vac; IEC60947)
10kA (400Vac; IEC60947)
7.5kA (440Vac; IEC60947)
Service short circuit current breaking capacity (Ics)
8kA (100Vac)
8kA (230Vac)
5kA (400Vac)
4kA (440Vac)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
(400Vac) 50 %
Trip unit type
Thermal-Magnetic (fixed)
Protection settings
Thermal protection (Overload) -- tripping threshold fixed at 5A
Mounting mode
Surface mounting (or DIN rail with optional adapter)
Dimensions
W54mm x H120mm x D90mm
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Earth leakage protection
Compliant with standard(s)
IEC 60947-2
EN 60947-2
UL 489
CSA C22.2 No.5-02
TUV approval CE marking
Equivalent to
NV50SVFU3P5A30
Rated impulse voltage (Uimp)
6 kV
Trip current rating
5 AT
Utilisation category
A
Rated Voltage (AC) - Phase-to-phase
100-440 V
Benefits
The all-new "World Super V Series (WS-V Series)" built with a new breaking technology is designed to respond to the individual market needs of the receiving and distribution and machineries.
This series is the result of revolutionary evolution
Equipped with a new cutoff technology to enhance interrupting performance
Compatible with the latest standards of various countries to deliver optimal performance according to individual needs.
Degree of pollution
2
MANUFACTURERS