Free shipping

Mitsubishi NV50-SVFU3P5A30 Molded Case Circuit Breaker (MCCB) with embedded earth leakage protection 3-poles 5A

$537.00

Order today and receive in 4 weeks (pay when ready):

$0.00

NV50-SVFU3P5A30
PREORDER
+

Description

Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB) - high-speed type - Mitsubishi (UL 489 Listed ELCBs (harmonic surge ready) - NF-S (standard class)) - 3-poles (3P) - Rated current 5A - Residual current sensitivity 30mA - Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947) - Short circuit current rating 14kA (240Vac; UL489) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection connection

Specifications

Primary brand
Mitsubishi

Main function
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / ELCB

Product series / family name
UL 489 Listed ELCBs (harmonic surge ready)

Sub-range name
NF-S (standard class)

Functions
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB)

Design
high-speed type

Poles
3-poles (3P)

Rated current
5A

Frame current rating
50 AF

Residual current sensitivity
30mA

Rated voltage (AC)
120-240Vac (UL 489)

Connection type
Front lugs or bars connection

Short circuit breaking rating
14kA (120Vac; UL489)
14kA (240Vac; UL489)

Ultimate short circuit current breaking capacity (Icu)
15kA (100Vac; IEC60947)
15kA (230Vac; IEC60947)
10kA (400Vac; IEC60947)
7.5kA (440Vac; IEC60947)

Service short circuit current breaking capacity (Ics)
8kA (100Vac)
8kA (230Vac)
5kA (400Vac)
4kA (440Vac)

Service short circuit current breaking capacity as a percentage of Icu (Ics%)
(400Vac) 50 %

Trip unit type
Thermal-Magnetic (fixed)

Protection settings
Thermal protection (Overload) -- tripping threshold fixed at 5A

Mounting mode
Surface mounting (or DIN rail with optional adapter)

Dimensions
W54mm x H120mm x D90mm

Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Earth leakage protection

Compliant with standard(s)
IEC 60947-2
EN 60947-2
UL 489
CSA C22.2 No.5-02
TUV approval CE marking

Equivalent to
NV50SVFU3P5A30

Rated impulse voltage (Uimp)
6 kV

Trip current rating
5 AT

Utilisation category
A

Rated Voltage (AC) - Phase-to-phase
100-440 V

Benefits
The all-new "World Super V Series (WS-V Series)" built with a new breaking technology is designed to respond to the individual market needs of the receiving and distribution and machineries.
This series is the result of revolutionary evolution
Equipped with a new cutoff technology to enhance interrupting performance
Compatible with the latest standards of various countries to deliver optimal performance according to individual needs.

Degree of pollution
2

MANUFACTURERS

Price history Price history