Description
Specifications
Model | EV-112U | |
Type | Non-shielded | |
Shape | M12 | |
Detecting distance | 8 mm 0.31" ±10>#/p### | |
Detectable object | Ferrous metals (see Characteristics for nonferrous metals) | |
Standard target | 30 x 30 mm 1.18" x 1.18" | |
Hysteresis | 20% max. of detecting distance, within -10 to +70°C 14 to 158°F | |
Response frequency | 600 Hz | |
Operation mode | N.O. | |
Temperature characteristics | ±10% max. of detecting distance, | |
Control output | 5 to 200 mA | |
Protection circuit | Reversed polarity, short-circuit, surge voltage | |
Cable length | 2 m 6.6' | |
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 20 % or less |
Current consumption (leakage | Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) | |
Residual voltage | Residual voltage: 3.6 V max. (with 2-m 6.6' cable) | |
Environmental resistance | Enclosure rating | IP67 |
Ambient temperature | -25 to +80 °C -13 to 176 °F (No freezing) | |
Relative humidity | 35 to 95 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Case material | Nickel-plated brass | |
Accessories | Nut × 2, toothed washer × 1, instruction manual | |
Weight | Approx. 110 g |
MANUFACTURERS
Price history
The price has not changed yet. We will show it on this chart once it changes