Description
Specifications
Model | SZ-V32X *1 | ||
Type | Multi-bank Type | ||
Detection capability | Minimum detectable object size | Diameter 20, 30, 40, 50, 70, 150 mm 0.79", 1.18", 1.57", 1.97", 2.76", 5.91" (depends on the setting) Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max. *2 | |
Detectable angle | 190° ( -5° to 185° ) | ||
Response time (ON to OFF) | Standard Mode | Scan Cycle A | 160 ms (2scans) to 1280 ms (16scans) *3 *4 |
Scan Cycle B | 168 ms (2scans) to 1344 ms (16scans) *3 *4 | ||
Scan Cycle C | 176 ms (2scans) to 1408 ms (16scans) *3 *4 | ||
High Speed Mode | Scan Cycle A | 80 ms (2scans) to 640 ms (16scans) *3 *4 | |
Scan Cycle B | 84 ms (2scans) to 672 ms (16scans) *3 *4 | ||
Scan Cycle C | 88 ms (2scans) to 704 ms (16scans) *3 *4 | ||
Response time (OFF to ON) | Response time (ON to OFF) + 150 ms | ||
Protection zone | Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" | 8.4 m 27.56' (Standard Mode) 5.7 m 18.70' (High Speed Mode) | |
Minimum detectable object size: 50 mm 1.97" | 5.6 m 18.37' (Standard Mode) 3.8 m 12.47' (High Speed Mode) | ||
Minimum detectable object size: 40 mm 1.57" | 4.3 m 14.11' (Standard Mode) 2.9 m 9.51' (High Speed Mode) | ||
Minimum detectable object size: 30 mm 1.18" | 2.9 m 9.51' (Standard Mode) 2.0 m 6.56' (High Speed Mode) | ||
Minimum detectable object size: 20 mm 0.79" | 1.6 m 5.25' (Standard Mode) 1.1 m 3.61' (High Speed Mode) | ||
Warning zone | Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" | 26 m 85.30' (Standard Mode) 23 m 75.46' (High Speed Mode) *5 | |
Minimum detectable object size: 50 mm 1.97" | 25 m 82.02' (Standard Mode) 21 m 68.90' (High Speed Mode) *5 | ||
Minimum detectable object size: 40 mm 1.57" | 24 m 78.74' (Standard Mode) 20 m 65.62’ (High Speed Mode) *5 | ||
Minimum detectable object size: 30 mm 1.18" | 23 m 75.46' (Standard Mode) 18 m 59.06' (High Speed Mode) *5 | ||
Minimum detectable object size: 20 mm 0.79" | 21 m 68.90' (Standard Mode) 15 m 49.21' (High Speed Mode) *5 | ||
Additional safety distance | 100 mm 3.94" *6 | ||
Maximum measurement distance | 60 m 196.85' *7 | ||
Maximum number of banks | Max. 32 banks | ||
Multiple scanner heads | Max. 3 scanner heads | ||
Camera monitoring area | Monitor area: over 190° (-5° to 185°) *8 | ||
Display | QVGA 2.2inch color LCD | ||
Light source | Type, wavelength | Infrared laser diode, 905 nm | |
Laser Class | IEC | Class1 IEC/EN60825-1 | |
FDA | Class1 FDA 21CFR 1040.10, 1040.11 (Laser Notice No.50) *9 | ||
JIS | Class1 JIS C6802 | ||
Control output (OSSD) | Output | Transistor outputs (NPN or PNP is selected in the software) | |
Number of outputs | 2 outputs | ||
Max. load current | 500 mA *10 | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m 16.40') | ||
OFF-state voltage | Max. 2.0 V (with a cable length of 5 m 16.40') | ||
Leakage current | Max. 1 mA *11 | ||
Max. capacitive load | 2.2 μF (with a load resistance of 100 Ω) | ||
Load wiring resistance | Max. 2.5 Ω | ||
Inputs | PNP | ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) | |
NPN | ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) | ||
Non-safety related output (AUX output) | Output type | Transistor outputs (NPN or PNP is selected by the dedicated PC software) | |
Number of outputs | 4 outputs | ||
Max. load current | Max. 50 mA | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m 16.40') | ||
Muting lamp | - | ||
Interface | USB | USB2.0 | |
Ethernet | Standard | - | |
Transmission rate | |||
Cable | |||
Connector | |||
Network function | |||
Cable length | Power and I/O cable | 30 m 98.43' or less *12 | |
Between scanner head and display unitc | 20 m 65.62' or less each *13 | ||
Ethernet cable | - | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE) |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR), IEC61508, EN61508, | ||
Rating | Power consumption | 11.8 W (without load), 55.0 W (with load) *14 | |
Power voltage | 24 VDC ±10% (Ripple P-P 10% or less): When using a converter power supply, 24 VDC +20%/-30%: When using a battery | ||
Environmental resistance | Enclosure rating | IP65(IEC60529) | |
Ambient light | Incandescent lamp: 1500 lux or less *15 | ||
Operating ambient temperature | -10 to +50°C 14 to 122°F (No freezing) | ||
Storage temperature | -25 to +60°C -13 to +140°F (No freezing) | ||
Operating relative humidity | 35% to 85% RH (No condensation) | ||
Storage relative humidity | 35% to 95% RH | ||
Vibration resistance | 10 to 55 Hz, 0.7 mm 0.03" compound amplitude, 20 sweeps each in X, Y, and Z directions | ||
Shock resistance | 100 m/s2 328.08 ft/s2 (Approx. 10 G) 16 ms pulse, in X, Y, Z directions 1000 times each axis | ||
Material | Scanner head | Main unit case | Magnesium |
Window | Polycarbonate, PEI | ||
Indicator part | Aluminum, PES | ||
Display unit | Case | Magnesium, PPS, Polycarbonate | |
System memory | Aluminum, PPE | ||
Weight | Approx. 2100 g | ||
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005).
*2 If the object to be detected moves parallel to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s 5.25 ft/s, regardless of the encoder setting.
*3 The response time, protection zone, and warning zone are affected by the operation mode.
*4 When using PROFIsafe, 6 ms is added to the response time. When using CIP Safety, 10ms is added to the response time.
*5 20% or more reflectance is necessary for the minimum detectable object in the warning zone.
*6 If there is a highly reflective background within 1.5 m 4.92' from the boundary of the protection zone, 200 mm 7.87" must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance.
*7 Even when using the network data output, the maximum measured output distance is 60 m 196.85'.
*8 Only applicable for the type with a camera.
*9 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*10 For the SZ-V04 type and the SZ-V32 type, the load current calculation of the OSSD output and AUX output is 1.5 A or less when using one scanner head, 1.0 A or less when using two scanner heads, and 0.5 A or less when using three scanner heads. For the SZ-V32N type, the load current calculation of the OSSD output and AUX output is 1.2 A or less when using one scanner head, 0.8 A or less when using two scanner heads, and 0.3 A or less when using three scanner heads.
*11 Includes when the power is OFF.
*12 10 m 32.81' or less when supplying power from a battery.
*13 When supplying power from a battery, the length of each connection cable should be 10 m 32.81' or less when using two scanner heads, and 5 m 16.40' or less when using three scanner heads.
*14 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation.
*15 An ambient light source should not be located within ±5° of the detection plane.
MANUFACTURERS
Price history
The price has not changed yet. We will show it on this chart once it changes