Please sign in so that we can notify you about a reply
Description
Variable Speed/Frequency Drive (VSD/VFD) / Inverter - US/CA/MX specification - Mitsubishi Electric (FREQROL FR-F700 series) - input 380Vac-480Vac (3-phase/3P) - 90kW / 125HP - 180A - frequency (output) 0.5-400Hz - with Modbus RTU communication capability - IP00 - input voltage nominal values 400Vac / 415Vac / 440Vac - equivalent to FRF74002160NA
Specifications
Primary brand
Mitsubishi Electric
Main function
Variable Speed/Frequency Drive (VSD/VFD) / Inverter
Product series / family name
FREQROL FR-F700 series
Network frequency
(output) 0.5-400 Hz
Functions
Variable Speed/Frequency Drive (VSD/VFD) / Inverter
High carrier frequency PWM control
Maximum and minimum frequency settings
Frequency jump operation
External thermal relay input selection
Polarity reversible operation
Automatic restart after instantaneous power failure operation
Original operation continuation at instantaneous power failure
Commercial power supply-inverter switchover operation
Forward/reverse rotation prevention
Operation mode selection
PID control
Computer link operation (RS-485)
Design
US/CA/MX specification
Forced air cooling
Supply voltage (AC)
380Vac-480Vac
(400Vac / 415Vac / 440Vac)
Type of network
3-phase/3P
Rated current
180A
120% In for 60s / 150% In for 3s overload current rating (inverse-time characteristic)
Rated active power (kW)
90kW
Rated power (HP)
125HP
Protection functions
Overcurrent during acceleration
Overcurrent during constant speed
Overcurrent during deceleration
Overvoltage during acceleration
Overvoltage during constant speed
Overvoltage during deceleration
Inverter protection thermal operation
Motor protection thermal operation
Heatsink overheat
Instantaneous power failure occurrence
Undervoltage
Input phase failure
Motor overload
Output side earth (ground) fault overcurrent
Output phase failure
External thermal relay operation
PTC thermistor operation
Option alarm
Parameter error
PU disconnection
Retry count excess
CPU alarm
Operation panel power supply short circuit
24Vdc power output short-circuit
Output current detection value excess
Inrush resistance overheat
Communication alarm (inverter)
Analog input alarm
Internal circuit alarm (15V power supply)
Fan fault
Overcurrent stall prevention
Overvoltage stall prevention
Electronic thermal relay function pre-alarm
PU stop
Parameter write error
Copy operation error
Operation panel lock
Parameter copy alarm
Communication protocol
Modbus RTU
Digital inputs
1 x digital input (source/sink) (STF)
1 x digital input (source/sink) (STR)
1 x digital input (source/sink) (STOP)
1 x digital input (source/sink) (RH)
1 x digital input (source/sink) (RM)
1 x digital input (source/sink) (RL)
1 x digital input (source/sink) (JOG)
1 x digital input (source/sink) (RT)
1 x digital input (source/sink) (MRS)
1 x digital input (source/sink) (RES)
1 x digital input (source/sink) (AU/PTC)
1 x digital input (source/sink) (CS)
Digital outputs
1 x digital output (SPDT (Single Pole Double Throw contact A1/B1/C1) (programmable)
1 x digital output (SPDT Single Pole Double Throw contact A2/B2/C2) (programmable)
1 x digital output (sink/source open collector transistor) (RUN; programmable)
1 x digital output (sink/source open collector transistor) (SU; programmable)
1 x digital output (sink/source open collector transistor) (IPF; programmable)
1 x digital output (sink/source open collector transistor) (OL; programmable)
1 x digital output (sink/source open collector transistor) (FU; programmable)
1 x digital output (PTO Pulse Train Output)
Analog inputs
1 x analog input (0-5Vdc / 0-10Vdc / 0-20mA)
1 x analog input (0-5Vdc / 0-10Vdc)
1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA)
Analog outputs
1 x analog output (0-10Vdc)
Degree of protection
IP00
Rated apparent power (S)
137kVA
Application type
Fan
Pump
Order code / Manufacturer SKU
FR-F740-02160-NA
Compliant with standard(s)
UL
cUL
CE (Low Voltage Directive)
MANUFACTURERS
Price history
The price has not changed yet. We will show it on this chart once it changes