Molex SST-PB3-REM Profibus Remote Control Module

GENERIC / SUBSTITUTE, NEW, ORIGINAL PACKAGING, Source:SURPLUS
$2,395.00

Order today and receive in 4 weeks. Pay when ready:

$0.00

SST-PB3-REM
PREORDER
+

Description

Key features:

• Compatibility with any Rockwell Automation Logix™ controllers.

• Easier RSLogix5000 configuration using SST™ Profibus Configuration Tool exported L5X file. The L5X file contains I/O tags in UDT format with corresponding AOI(s).

• Several SST-PB3-REM modules may be connected to the same Ethernet Network.

• Two Ethernet ports with an embedded switch feature. 

• Supports up to five Listen-only connections.

• Supports Explicit Messaging for retrieving status and diagnostics information, as well as I/O data.

• Windows engineering console to configure and diagnose Profibus network and devices.

• Includes a CommDTM driver to provide transparent access from FDT software such as FactoryTalk® AssetCentre, PACTware™, FieldCARE™ or asset management tools to the Profibus devices.

• EtherNet/IP Adapter ODVA certified.

• PNO certified: Profibus DP-V0, V1 Master and DP-V0 Slave.

• Profibus features:

• Acts as Profibus DP-V0 and DP-V1 Master.

• Acts as Profibus DP-V0 Slave.

• Able to run Profibus DP-V0 Master and Slave modes simultaneously.

• Supports all standard Profibus baud rates (9.6Kbps to 12Mbps).

• As Profibus DP-V0 Master is able to scan up to 125 devices slave devices with a total of 1996 bytes input and 1980 bytes output data.

• As Profibus DP-V0 Master supports and scans up to 244 bytes of input data and 244 bytes of output data per slave.

• As Profibus DP-V0 Master supports Sync and Freeze commands.

• Supports the following DP-V1 Master services:  Class-1: MSAC1_Read, MSAC1_Write  Class-2: MSAC2_Initiate, MSAC2_Read, MSAC2_Write, MSAC2_Abort 


How It Works:

SST-PB3-REM combines the functionality of an EtherNet/IP Adapter with that of a Profibus Master or/and Slave which enables a controller acting as an EtherNet/IP Scanner to transmit and receive data on the Profibus network. There are four possible communication paths between the EtherNet/IP Scanner and the Adapter embedded in the PB3 Remote Module:

• Exclusive Owner connection(s) for I/O exchange.

• Input-only connection for retrieving status information. When configuring an Exclusive Owner connection in RSLogix5000 this connection is automatically opened when the user selects Data SINT with Status for the “Comm Format” parameter.

• Listen-only connection(s) for monitoring. Corresponding Exclusive Owner connection(s) must exist.

• Explicit Messaging for sending various commands, DP-V1 messaging and I/O exchange. No implicit connection(s) is required. The EtherNet/IP and Profibus scan cycles are independent from each other (see Figure 2.2-1 below