Please sign in so that we can notify you about a reply
Description
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB) - high-speed type - Mitsubishi (UL 489 Listed ELCBs (harmonic surge ready) - NF-S (standard class)) - 3-poles (3P) - Rated current 15A - Residual current sensitivity 100mA / 200mA / 500mA (adjustable) - Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947) - Short circuit current rating 30kA (480Vac; UL489) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection connection.
Specifications
Primary brand
Mitsubishi
Main function
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / ELCB
Product series / family name
UL 489 Listed ELCBs (harmonic surge ready)
Sub-range name
NF-S (standard class)
Functions
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB)
Design
high-speed type
Poles
3-poles (3P)
Rated current
15A
Trip current rating
15 AT
Frame current rating
125 AF
Residual current sensitivity
100mA / 200mA / 500mA (adjustable)
Rated voltage (AC)
120-480Vac (UL 489)
Rated impulse voltage (Uimp)
6 kV
Connection type
Front lugs or bars connection
Short circuit breaking rating
50kA (120Vac; UL489)
50kA (240Vac; UL489)
30kA (480Vac; UL489)
Ultimate short circuit current breaking capacity (Icu)
50kA (100Vac; IEC60947)
50kA (230Vac; IEC60947)
30kA (400Vac; IEC60947)
30kA (440Vac; IEC60947)
Service short circuit current breaking capacity (Ics)
25kA (100Vac)
25kA (230Vac)
15kA (400Vac)
15kA (440Vac)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
(400Vac) 50 %
Trip unit type
Thermal-Magnetic (fixed)
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Earth leakage protection
Protection settings
Thermal protection (Overload) -- tripping threshold fixed at 15A
Dimensions
W90mm x H160mm x D90mm
Utilisation category
A
Manufacturer product status
Commercialized
Rated Voltage (AC) - Phase-to-phase
100-440 V
Compliant with standard(s)
IEC 60947-2
EN 60947-2
UL 489
CSA C22.2 No.5-02
TUV approval CE marking
Benefits
The all-new "World Super V Series (WS-V Series)" built with a new breaking technology is designed to respond to the individual market needs of the receiving and distribution and machineries.
This series is the result of revolutionary evolution
Equipped with a new cutoff technology to enhance interrupting performance
Compatible with the latest standards of various countries to deliver optimal performance according to individual needs.
Degree of pollution
2
MANUFACTURERS
Price history
The price has not changed yet. We will show it on this chart once it changes