Phoenix Contact 2905744 | 29 05 74 4 Electronic circuit breaker - CBM E8 24DC/0.5-10A NO-R

Brand:PHOENIX CONTACT, Condition:new
$685.00

Order today and receive in 4 weeks (pay when ready):

$0.00

2905744
PREORDER
+

Description

Multi-channel, electronic circuit breaker with active current limitation for protecting eight loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails.


Product properties

TypeDIN rail module, one-piece 
Product typeDevice circuit breakers
Number of positions1
No. of channels8
Insulation characteristics
Protection classIII
Pollution degree2

Electrical properties

No. of channels8
General
Operating voltage18 V DC ... 30 V DC
Rated voltage24 V DC
Rated current INmax. 80 A DC (for double supply IN+ with at least 2 x 6 mm²)
max. 70 A DC (for UL 2367)
Rated current IN0.5 / 1 / 2 / 4 / 6 / 10 A DC (adjustable per output channel)
Rated current (pre-adjusted)0.5 A
Rated surge voltage0.5 kV
Tripping methodE (electronic)
Feedback resistancemax. 35 V DC
Required backup fuseOnly required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
Short-circuit switching capacity300 A
Dielectric strengthmax. 30 V DC (Load circuit)
Active current limitationtyp. 2.0 x IN (0.5 - 1 A)
typ. 1.5 x IN (2 - 10 A)
Fuseelectronic
Efficiency> 99 >#/td###
Closed circuit current I0typ. 50 mA
Power dissipation1.2 W (No-load operation)
17.2 W (Nominal operation)
Module initialization time3.3 s
Waiting time after switch off of a channel10 s (at overload / short circuit)
Measuring tolerance Ityp. 40 % (0.5 A ... 1 A)
typ. 10 % (2 - 10 A)
Temperature derating40 A DC (at 70°C (65°C for UL 2367))
50 A DC (at 60 °C)
60 A DC (at 50 °C)
70 A DC (at 40 °C)
80 A DC (at 40 °C)
70 A DC (at 40°C for UL 2367)
MTBF (IEC 61709, SN 29500)1304293 h (at 25 °C)
858501 h (at 40 °C)
440048 h (at 60 °C)
Fail-safe element15 A DC (per output channel)
Shutdown time0.02 s (> 1.3 x IN)
30 s (1.1 ... 1.3 x IN)
Undervoltage switch-off≤ 17.8 V DC (active)
≥ 19 V DC (inactive)
Overvoltage switch-off≥ 30.5 V DC (active)
≤ 29.5 V DC (inactive)
Max. capacitive load75000 µF
Input voltage range7 V DC ... 30 V DC (Reset with falling edge)
Current consumptiontyp. 0.4 mA (at 24 V DC)
Pulse length≥ 50 ms (High signal)
≥ 50 ms (Low signal)
Voltage< 5 V DC (Low signal)
> 8 V DC (High signal)
Output voltage24 V DC
Output currentmax. 20 mA (when I > 80% at at least one channel)
Indicator/remote signaling
Connection nameRemote indication circuit
Switching functionN/O contact
Operating voltage0 V DC ... 30 V DC
Operating current1 mA DC ... 100 mA DC

Connection data

Main circuit IN+
Connection methodPush-in connection
Stripping length18 mm
Conductor cross section solid0.75 mm² ... 16 mm²
Conductor cross section AWG20 ... 4
Conductor cross section, flexible, with ferrule, with plastic sleeve0.75 mm² ... 10 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.75 mm² ... 16 mm²
Main circuit IN+
Connection methodPush-in connection
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Main circuit IN+
Connection methodPush-in connection
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Remote indication circuit
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve1.5 mm² ... 0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²

LED signaling

DC OK LED offoff (No supply voltage)
DC OK LED yellowlit (Undervoltage active, voltage ≤ 17.8 V, active channels switched off and channel LEDs are lit red)
flashing (Undervoltage switch-off inactive, device was in undervoltage switch-off)
DC OK LED greenlit (Operating voltage in nominal range 18 ... 30 V)
DC OK LED redlit (Overvoltage switch-off active, voltage ≥ 30.5 V, channels switched off and channel LEDs are lit red)
flashing (Overvoltage switch-off inactive, device was in overvoltage shutdown)
Channel LED offoff (Channel switched off)
Channel LED yellowlit (Channel switched on, channel load > 80% )
Channel LED yellow-greenflashing (Channel switched on, nominal current assistant active)
Channel LED greenlit (Channel switched on)
flashing (Channel switched on, programming mode active)
Channel LED redlit (Channel switched off, over- or undervoltage active)
ON temporarily (Channel switched off, 10 s cool-down phase, overload or short-circuit release)
flashing (Channel switched off, ready to be switched back on, overload or short-circuit release)
Channel LED red-yellowflashing (Channel switched on, overload mode, capacity approximately 110 ... 130% , shutdown after 30 s)
Channel LED red-greenflashing (Channel switched off, programming mode active, current adjustment after overload or short-circuit release)

Dimensions

Dimensional drawing
Width41 mm
Height130 mm
Depth121 mm (incl. DIN rail 7.5 mm)

Material specifications

Colorlight grey RAL 7035
MaterialPC (Housing)
PA 6.6 (Terminal blocks)
PC (Light emission area)
PBT-FR17 (Base latch)
POM (Potentiometer axis)
Flammability rating according to UL 94V-0