Phoenix Contact QUINT-PS/1AC/24DC/5/F | 2939263 Power supply unit [NEW OLD STOCK]

$552.00
QUINT-PS/1AC/24DC/5/F
1 in stock
+

Primary-switched power supply unit QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 24 V DC / 40 A

QUINT POWER power supplies with maximum functionality
QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur.
Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V DC

Technical Data

AC operation
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC
Derating< 100 V AC (1 %/V)
Input voltage range AC85 V AC ... 264 V AC
Input voltage range DC90 V DC ... 300 V DC (UL 508: ≤ 250 V DC)
Electric strength, max.300 V AC
Voltage type of supply voltageAC
Inrush current< 15 A (typical)
Inrush current integral (I2t)< 1.7 A2s
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Mains buffering time> 35 ms (120 V AC)
> 35 ms (230 V AC)
Current consumption8.8 A (120 V AC)
4.6 A (230 V AC)
9.5 A (110 V DC)
4.7 A (220 V DC)
Nominal power consumption1157 VA
Protective circuitTransient surge protection; Varistor, gas-filled surge arrester
Power factor (cos phi)0.88
Typical response time< 0.7 s
Input fuse20 A (slow-blow, internal)
Permissible backup fuseB16 B25 AC:
Permissible DC backup fuseDC: Connect a suitable fuse upstream
Recommended breaker for input protection16 A ... 20 A (AC: Characteristics B, C, D, K)
Discharge current to PE< 3.5 mA
DC operation
Nominal input voltage range120 V DC ... 300 V DC (UL 508: ≤ 250 V DC)
Input voltage range90 V DC ... 300 V DC (UL 508: ≤ 250 V DC)
Derating< 120 V DC (0.5 %/V)
Voltage type of supply voltageDC

Connection

Efficiency> 92 % (for 230 V AC and nominal values)
Output characteristicU/I
Nominal output voltage24 V DC ±1 >#/td###
Setting range of the output voltage (USet)18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)40 A (-25 °C ... 60 °C, UOUT = 24 V DC)
POWER BOOST (IBoost)45 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
Selective Fuse Breaking (ISFB)215 A (12 ms)
Magnetic circuit breaker trippingB2 / B4 / B6 / B10 / B16 / B25 / C2 / C4 / C6 / C13
Derating60 °C ... 70 °C (2.5%/K)
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 35 V DC
Residual ripple< 30 mVPP (with nominal values)
Short-circuit-proofyes
Output power960 W
Maximum no-load power dissipation14 W
Power loss nominal load max.80 W
Rise time< 0.1 s (UOUT (10 % ... 90 %))
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes
Signal: DC OK active
Output descriptionUOUT > 0.9 x UN: High signal
Switching voltage range18 V DC ... 24 V DC
Output voltage+ 24 V DC
Maximum inrush current≤ 20 mA (short-circuit-proof)
Continuous load current≤ 20 mA
Signal: DC OK floating
Output descriptionRelay contact, UOUT > 0.9 x UN: Contact closed
Maximum switching voltage30 V AC
24 V DC
Maximum inrush current0.5 A
1 A
Continuous load current1 A
Signal: POWER BOOST, active
Output descriptionIOUT < IN: High signal
Switching voltage range18 V DC ... 24 V DC
Output voltage+ 24 V DC
Maximum inrush current≤ 20 mA (short-circuit-proof)
Continuous load current≤ 20 mA
Input
Connection methodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.14
Conductor cross section AWG max.10
Stripping length7 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Output
Connection methodScrew connection
Conductor cross section, rigid min.0.5 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section AWG min.8
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4
Tightening torque, min1.2 Nm
Tightening torque max1.5 Nm
Signal
Connection methodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.10
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signaling

Types of signalingLED
Active switching output
Relay contact










Brands:
PHOENIX CONTACT
Condition:
new

Price history Price history