- Red/green display for clear identification of the acceptable range
- The process connection can be rotated for optimum alignment
- With long-term stability thanks to high overload protection
- Robust design for use in harsh industrial environments
Product characteristics
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
Measuring range | 0...250 bar | 0...3625 psi | 0...25 MPa |
|
Process connection | threaded connection 1/4" NPT Internal thread |
Application
System | gold-plated contacts |
Measuring element | metallic thin film cell |
Application | for industrial applications |
Media | liquids and gases |
Medium temperature[°C] | -25...80 |
Min. bursting pressure | |
Pressure rating | |
Vacuum resistance | |
Type of pressure | relative pressure |
MAWP (for applications according to CRN) | |
Electrical data
Operating voltage[V] | 18...30 DC; (to SELV/PELV) |
Current consumption[mA] | < 35 |
Min. insulation resistance[MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time[s] | 0.3 |
Integrated watchdog | yes |
Inputs / outputs
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
Outputs
Total number of outputs | 2 |
Output signal | switching signal; analog signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC[V] | 2 |
Permanent current rating of switching output DC[mA] | 250 |
Switching frequency DC[Hz] | < 500 |
Number of analog outputs | 1 |
Analog current output[mA] | 4...20; (scalable 1:5) |
Max. load[Ω] | 500 |
Analog voltage output[V] | 0...10; (scalable 1:5) |
Min. load resistance[Ω] | 2000 |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring/setting range
Measuring range | 0...250 bar | 0...3625 psi | 0...25 MPa |
|
Analog start point | 0...200 bar | 0...2900 psi | 0...20 MPa |
|
Analog end point | 50...250 bar | 725...3625 psi | 5...25 MPa |
|
Factory setting / CMPT = 2 |
---|
Set point SP | 1.5...250 bar | 25...3625 psi | 0.15...25 MPa |
|
Reset point rP | 0.5...249 bar | 10...3610 psi | 0.05...24.9 MPa |
|
Min. difference between SP and rP | |
In steps of | |
Status_B High Resolution / CMPT = 3 |
---|
Set point SP | 1.6...250 bar | 23...3626 psi | 0.16...25 MPa |
|
Reset point rP | 0.5...249 bar | 8...3611 psi | 0.05...24.9 MPa |
|
Min. difference between SP and rP | |
In steps of | |
Accuracy / deviations
Switch point accuracy[% of the span] | < ± 0,4; (Turn down 1:1) |
Repeatability[% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation[% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation[% of the span] | < ± 0,1; (Turn down 1:1) |
Long-term stability[% of the span] | < ± 0,05; (Turn down 1:1; per 6 months) |
Temperature coefficient zero point[% of the span / 10 K] | 0,2; (-25...80 °C) |
Temperature coefficient span[% of the span / 10 K] | 0,2; (-25...80 °C) |
Notes on the accuracy / deviation | switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1>#/td### |
Reaction times
Response time[ms] | < 1.5 |
Delay time programmable dS, dr[s] | 0...50 |
Damping process value dAP[s] | 0...4 |
Damping for the analog output dAA[s] | 0...4 |
Max. response time analog output[ms] | 3 |
Software / programming
Parameter setting options | hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Interfaces
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
SIO mode | yes |
Required master port class | A; (when pin 2 not connected: B) |
Supported DeviceIDs | Type of operation | DeviceID |
---|
Factory setting / CMPT = 2 | 470 | Status_B High Resolution / CMPT = 3 | 986 |
|
Note | For further information please see the IODD PDF file at "Downloads" |
|
Factory setting / CMPT = 2 |
---|
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time[ms] | 2.3 |
IO-Link resolution pressure[bar] | 0.1 |
IO-Link process data (cyclical) | Function | bit length |
---|
pressure | 14 | binary switching information | 2 |
|
IO-Link functions (acyclical) | application specific tag |
Status_B High Resolution / CMPT = 3 |
---|
Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time[ms] | 3 |
IO-Link resolution pressure[bar] | 0.1 |
IO-Link process data (cyclical) | Function | bit length |
---|
pressure | 16 | device status | 4 | binary switching information | 2 |
|
IO-Link functions (acyclical) | application specific tag |
Operating conditions
Ambient temperature[°C] | -25...80 |
Storage temperature[°C] | -40...100 |
Protection | IP 65; IP 67 |
Tests / approvals
EMC | DIN EN 61000-6-2 | | DIN EN 61000-6-3 | |
|
Shock resistance | DIN EN 60068-2-27 | 50 g (11 ms) |
|
Vibration resistance | DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
MTTF[years] | 124 |
UL approval | |
Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
>td >Restrictor element integrated
Weight[g] | 219.5 |
Housing | tubular |
Dimensions[mm] | Ø 34 / L = 90.7 |
Material | stainless steel (630/1.4542/17-4 PH); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts) | stainless steel (630/1.4542/17-4 PH) |
Min. pressure cycles | 100 million |
Tightening torque[Nm] | > 50; (Depends on lubrication, seal and pressure rating) |
Process connection | |
no (can be retrofitted) |
Displays / operating elements
Display | Display unit | 3 x LED, green (bar, psi, MPa) | Switching status | 2 x LED, yellow | Measured values | alphanumeric display, red/green 4-digit |
|
Remarks
Electrical connection
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — PN2271-01 — 01.03.2024 —