Description
This Altivar 12 variable speed drive can feed single phase asynchronous motors. It works at a rated power up to 0.55kW / 0.75hp and a rated voltage from 200V to 240V AC. It is designed with heatsink for normal environments and fan-cooled enclosure. Transient overtorque function prevents stoppages by unjamming the machine with extra torque, when needed, this reduces downtime and maintenance costs. It features underload and overload detection, this contribute to protect your installation. The Altivar 12 drive integrates as standard the Modbus communication protocol, which can be accessed via the RJ45 connector located on the underside of the drive. It is designed for simple industry and commercial machines and appliances, such as conveyors, pumps, extractors, access barriers and treadmills. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime. It features an optimized application of power and torque for ventilation and pumping applications, this allows up to 30% energy savings.
Main
Range of Product | Altivar 12 |
---|---|
Product or Component Type | Variable speed drive |
Product Specific Application | Simple machine |
Mounting Mode | Cabinet mount |
communication port protocol | Modbus |
supply frequency | 50/60 Hz +/- 5 >#/span### |
[Us] rated supply voltage | 200...240 V - 15...10 >#/span### |
nominal output current | 3.5 A |
Maximum Horse Power Rating | 0.75 hp |
motor power kW | 0.55 kW |
Maximum Horse Power Rating | 0.75 hp |
EMC filter | Integrated |
IP degree of protection | IP20 |
Complementary
discrete input number | 4 |
---|---|
discrete output number | 2 |
analogue input number | 1 |
analogue output number | 1 |
relay output number | 1 |
physical interface | 2-wire RS 485 |
Connector Type | 1 RJ45 |
continuous output current | 3.5 A 4 kHz |
method of access | Server Modbus serial |
speed drive output frequency | 0.5…400 Hz |
speed range | 1…20 |
sampling duration | 20 ms +/- 1 ms logic input 10 ms analogue input |
linearity error | +/- 0.3 % of maximum value analogue input |
frequency resolution | Analog input converter A/D, 10 bits Display unit 0.1 Hz |
time constant | 20 ms +/- 1 ms for reference change |
Transmission Rate | 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
transmission frame | RTU |
number of addresses | 1…247 |
data format | 8 bits, configurable odd, even or no parity |
communication service | Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
type of polarization | No impedance |
4 quadrant operation possible | False |
asynchronous motor control profile | Voltage/frequency ratio (V/f) Quadratic voltage/frequency ratio Sensorless flux vector control |
maximum output frequency | 4 kHz |
transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor |
acceleration and deceleration ramps | Linear from 0 to 999.9 s S U |
motor slip compensation | Preset in factory Adjustable |
switching frequency | 2...16 kHz adjustable 4...16 kHz with derating factor |
nominal switching frequency | 4 kHz |
braking to standstill | By DC injection |
brake chopper integrated | False |
line current | 8.0 A 100 V heavy duty) 6.7 A 120 V heavy duty) |
Maximum Input Current per Phase | 6.7 A |
maximum output voltage | 240 V |
apparent power | 1.6 kVA 240 V heavy duty) |
maximum transient current | 5.3 A 60 s heavy duty) 5.8 A 2 s heavy duty) |
Network Frequency | 50-60 Hz |
relative symmetric network frequency tolerance | 5 >#/span### |
prospective line Isc | 1 kA |
base load current at high overload | 3.5 A |
power dissipation in W | Natural 34.0 W |
with safety function Safely Limited Speed (SLS) | False |
with safety function Safe brake management (SBC/SBT) | False |
with safety function Safe Operating Stop (SOS) | False |
with safety function Safe Position (SP) | False |
with safety function Safe programmable logic | False |
with safety function Safe Speed Monitor (SSM) | False |
with safety function Safe Stop 1 (SS1) | False |
with sft fct Safe Stop 2 (SS2) | False |
with safety function Safe torque off (STO) | False |
with safety function Safely Limited Position (SLP) | False |
with safety function Safe Direction (SDI) | False |
protection type | Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
tightening torque | 7.08 lbf.in (0.8 N.m) |
insulation | Electrical between power and control |
Quantity per Set | Set of 1 |
Width | 2.83 in (72 mm) |
Height | 5.63 in (143 mm) |
Depth | 5.17 in (131.2 mm) |
Net Weight | 1.76 lb(US) (0.8 kg) |
Environment
operating altitude | > 3280.84...6561.68 ft (> 1000...2000 m) with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating |
---|---|
operating position | Vertical +/- 10 degree |
Product Certifications | NOM CSA C-tick br>GOST RCM KC |
marking | CE |
standards | UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 |
assembly style | With heat sink |
electromagnetic compatibility | Electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 Surge immunity test level 3 EN/IEC 61000-4-5 Voltage dips and interruptions immunity test EN/IEC 61000-4-11 |
environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
overvoltage category | Class III |
regulation loop | Adjustable PID regulator |
electromagnetic emission | Radiated emissions environment 1 category C2 EN/IEC 61800-3 2...16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <16.40 ft (5 m) Conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2...12 kHz shielded motor cable <16.40 ft (5 m) Conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <32.81 ft (10 m) Conducted emissions with additional EMC filter environment 1 category C1 EN/IEC 61800-3 4...12 kHz shielded motor cable <65.62 ft (20 m) Conducted emissions with additional EMC filter environment 1 category C2 EN/IEC 61800-3 4...12 kHz shielded motor cable <164.04 ft (50 m) Conducted emissions with additional EMC filter environment 2 category C3 EN/IEC 61800-3 4...12 kHz shielded motor cable <164.04 ft (50 m) |
vibration resistance | 1 gn 13…200 Hz)EN/IEC 60068-2-6 1.5 mm peak to peak 3…13 Hz) - drive unmounted on symmetrical DIN rail - EN/IEC 60068-2-6 |
shock resistance | 15 gn 11 ms EN/IEC 60068-2-27 |
relative humidity | 5…95 % without condensation IEC 60068-2-3 5…95 % without dripping water IEC 60068-2-3 |
noise level | 0 dB |
pollution degree | 2 |
ambient air transport temperature | -13…158 °F (-25…70 °C) |
ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating 104…140 °F (40…60 °C) with current derating 2.2 % per °C |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Ordering and shipping details
Category | 22042-ATV12 DRIVE AND ACCESSORIES |
---|---|
Discount Schedule | CP4B |
GTIN | 3606480071065 |
Returnability | Yes |
Country of origin | ID |
Packing Units
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 4.17 in (10.6 cm) |
Package 1 Width | 7.32 in (18.6 cm) |
Package 1 Length | 7.32 in (18.6 cm) |
Package 1 Weight | 2.52 lb(US) (1.141 kg) |
MANUFACTURERS
Price history