TeSys U standard power base, 3 poles (3NO), 12A/690V, to be completed with a control unit LUC to form a TeSys U starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" starter controller with basic or advanced protection and control functions. It is equipped with a control terminal block, and blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Main

rangeTeSys
product nameTeSys Ultra
device short nameLUB
Product or Component TypeNon reversing power base
Device ApplicationMotor control
Motor protection
poles description3P
suitability for isolationYes
[Ue] rated operational voltage690 V AC power circuit
network frequency40...60 Hz
[Ith] conventional free air thermal current12 A
[Ie] rated operational current12 A <= 440 V
12 A 500 V
9 A 690 V
utilisation categoryAC-43
AC-44
AC-41
[Ics] rated service breaking capacity50 kA 230 V
50 kA 440 V
10 kA 500 V
4 kA 690 V
auxiliary contact composition1 NO + 1 NC
auxiliary contacts typeLinked contacts 1 NO + 1 NC) IEC 60947-4-1
Mirror contact 1 NC) IEC 60947-1
[Uc] control circuit voltage24 V AC 50/60 Hz
24 V DC
48...72 V AC 50/60 Hz
48...72 V DC
110...240 V AC 50/60 Hz
110...220 V DC

Complementary

typical current consumption130 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
140 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
150 mA 24 V DC I maximum while closing with LUCM
280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
35 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
60 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
70 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
70 mA 24 V DC I rms sealed with LUCM
heat dissipation2 W control circuit with LUCA, LUCB, LUCC, LUCD
1.7 W control circuit with LUCM
safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
operating time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit
50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit
60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit
70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit
75 ms closing with LUCM control circuit
mechanical durability15 Mcycles
maximum operating rate3600 cyc/h
Product CertificationsCEbr>CSA
CCC
EAC
ASEFA
ATEX
Marine
standardsEN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
[Ui] rated insulation voltage690 V IEC 60947-6-2 3)
600 V UL 60947-4-1
600 V CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kVIEC 60947-6-2
safe separation of circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N
400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
fixing modeClipped DIN rail)
Screw-fixed plate)
connections - terminalsControl circuit screw clamp terminals 1 0.00…0.00 in² (0.34…1.5 mm²) flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) flexible without cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) rigid
Control circuit screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) rigid
Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²) rigid
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) flexible with cable end
Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) flexible with cable end
Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) rigid
Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) flexible without cable end
tightening torqueControl circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) flat 0.20 in (5 mm)
Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) Philips no 1 0.20 in (5 mm)
Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) flat 0.24 in (6 mm)
Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) Philips No 2 0.24 in (6 mm)
Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) pozidriv No 2 0.24 in (6 mm)
Width1.77 in (45 mm)
Height6.06 in (154 mm)
Depth4.96 in (126 mm)
Net Weight1.98 lb(US) (0.9 kg)
compatibility codeLUB

Environment>th >ambient air temperature for operation

IP degree of protectionIP20 IEC 60947-1 front panel and wired terminals)
IP20 IEC 60947-1 other faces)
IP40 IEC 60947-1 front panel outside connection zone)
protective treatment
-13…140 °F (-25…60 °C) with LUCM
-13…158 °F (-25…70 °C) with LUCA, LUCB, LUCC, LUCD
Ambient Air Temperature for Storage-40…185 °F (-40…85 °C)
fire resistance1760 °F (960 °C) parts supporting live components IEC 60695-2-12
1202 °F (650 °C) IEC 60695-2-12
operating altitude6561.68 ft (2000 m)
shock resistance10 gn power poles open IEC 60068-2-27
15 gn power poles closed IEC 60068-2-27
vibration resistance2 gn 5…300 Hz) power poles open IEC 60068-2-27
4 gn 5…300 Hz) power poles closed IEC 60068-2-27
resistance to electrostatic discharge8 kV 3 in open air IEC 61000-4-2
8 kV 4 on contact IEC 61000-4-2
resistance to radiated fields9.14 V/m (10 V/m) 3 IEC 61000-4-3
resistance to fast transients2 kV 3 serial link IEC 61000-4-4
4 kV 4 all circuits except for serial link IEC 61000-4-4
non-dissipating shock wave1 kV serial mode 24...240 V AC IEC 60947-6-2
1 kV serial mode 48...220 V DC IEC 60947-6-2
2 kV common mode 24...240 V AC IEC 60947-6-2
2 kV common mode 48...220 V DC IEC 60947-6-2
immunity to radioelectric fields10 V IEC 61000-4-6
immunity to microbreaks3 ms control circuit
immunity to voltage dips70 % / 500 ms IEC 61000-4-11

Ordering and shipping details

Category22396-TESYS U - SELF PRTCTD STARTER (LUB)
Discount ScheduleI11
GTIN3389110362770
ReturnabilityYes
Country of originFR

Packing Units

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.05 in (5.2 cm)
Package 1 Width5.51 in (14 cm)
Package 1 Length6.69 in (17 cm)
Package 1 Weight29.88 oz (847 g)
Unit Type of Package 2S03
Number of Units in Package 210
Package 2 Height11.81 in (30 cm)
Package 2 Width11.81 in (30 cm)
Package 2 Length15.75 in (40 cm)
Package 2 Weight19.82 lb(US) (8.988 kg)
Unit Type of Package 3P06
Number of Units in Package 380
Package 3 Height29.53 in (75 cm)
Package 3 Width23.62 in (60 cm)
Package 3 Length31.50 in (80 cm)
Package 3 Weight190.93 lb(US) (86.604 kg)