-Number of direction of rotation to be controlled is 1
-Type of control to be achieved is Basic control
-Modular, plug & play structure helps you to perform quick maintenance
-Direct access to detailed information for every motor starter of your installation
-Advanced motor management system
Description
TeSys U standard power base, 3 poles (3NO), 32A/690V, to be completed with a control unit LUC to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" starter controller with basic or advanced protection and control functions. It is equipped with a control terminal block, and blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications
Range | TeSys |
---|---|
Product name | TeSys Ultra |
Device short name | LUB |
Product or Component Type | Non reversing power base |
Device Application | Motor control Motor protection |
Poles description | 3P |
Suitability for isolation | Yes |
[Ue] rated operational voltage | 690 V AC power circuit |
Network frequency | 40...60 Hz |
[Ith] conventional free air thermal current | 32 A |
[Ie] rated operational current | 28.5 A <= 440 V 23 A 500 V 21 A 690 V |
utilisation category | AC-43 AC-44 AC-41 |
[Ics] rated service breaking capacity | 50 kA 230 V 50 kA 440 V 10 kA 500 V 4 kA 690 V |
Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Linked contacts 1 NO + 1 NC) IEC 60947-4-1 Mirror contact 1 NC) IEC 60947-1 |
[Uc] control circuit voltage | 24 V AC 50/60 Hz 24 V DC 48...72 V AC 50/60 Hz 48...72 V DC 110...240 V AC 50/60 Hz 110...220 V DC |
Complementary
Typical current consumption | 200 mA 24 V DC I maximum while closing with LUCM 220 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 220 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 25 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 25 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 45 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 45 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 75 mA 24 V DC I rms sealed with LUCM 80 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 90 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD |
---|---|
Heat dissipation | 3 W control circuit with LUCA, LUCB, LUCC, LUCD 1.8 W control circuit with LUCM |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Operating time | 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit 65 ms closing with LUCM control circuit |
Mechanical durability | 15 Mcycles |
Maximum operating rate | 3600 cyc/h |
Product Certifications | CE br>CSA CCC EAC ASEFA ATEX Marine |
Standards | EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier |
[Ui] rated insulation voltage | 690 V IEC 60947-6-2 3) 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 |
[Uimp] rated impulse withstand voltage | 6 kVIEC 60947-6-2 |
Safe separation of circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N |
Fixing mode | Clipped DIN rail) Screw-fixed plate) |
Connections - terminals | Control circuit screw clamp terminals 1 0.00…0.00 in² (0.34…1.5 mm²) flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) flexible without cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) rigid Control circuit screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) rigid Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²) rigid Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) flexible with cable end Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²) flexible without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) flexible with cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) rigid Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) flexible without cable end |
Tightening torque | Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) flat 0.20 in (5 mm) Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) Philips no 1 0.20 in (5 mm) Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) flat 0.24 in (6 mm) Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) Philips No 2 0.24 in (6 mm) Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) pozidriv No 2 0.24 in (6 mm) |
Width | 1.77 in (45 mm) |
Height | 6.06 in (154 mm) |
Depth | 4.96 in (126 mm) |
Net Weight | 1.98 lb(US) (0.9 kg) |
Compatibility code | LUB |
Environment>th >Ambient air temperature for operation
IP degree of protection | IP20 IEC 60947-1 front panel and wired terminals) IP20 IEC 60947-1 other faces) IP40 IEC 60947-1 front panel outside connection zone) |
---|---|
Protective treatment | |
-13…140 °F (-25…60 °C) with LUCM -13…158 °F (-25…70 °C) with LUCA, LUCB, LUCC, LUCD | |
Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
Fire resistance | 1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12 |
Operating altitude | 6561.68 ft (2000 m) |
Shock resistance | 10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27 |
Vibration resistance | 2 gn 5…300 Hz) power poles open IEC 60068-2-27 4 gn 5…300 Hz) power poles closed IEC 60068-2-27 |
Resistance to electrostatic discharge | 8 kV 3 in open air IEC 61000-4-2 8 kV 4 on contact IEC 61000-4-2 |
Resistance to radiated fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Resistance to fast transients | 2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Non-dissipating shock wave | 1 kV serial mode 24...240 V AC IEC 60947-6-2 1 kV serial mode 48...220 V DC IEC 60947-6-2 2 kV common mode 24...240 V AC IEC 60947-6-2 2 kV common mode 48...220 V DC IEC 60947-6-2 |
Immunity to radioelectric fields | 10 V IEC 61000-4-6 |
Immunity to microbreaks | 3 ms control circuit |
Immunity to voltage dips | 70 % / 500 ms IEC 61000-4-11 |
Ordering and shipping details
Category | 22396-TESYS U - SELF PRTCTD STARTER (LUB) |
---|---|
Discount Schedule | I11 |
GTIN | 3389110362787 |
Returnability | Yes |
Country of origin | FR |
Packing Units
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 2.17 in (5.500 cm) |
Package 1 Width | 5.43 in (13.800 cm) |
Package 1 Length | 6.65 in (16.900 cm) |
Package 1 Weight | 29.88 oz (847.000 g) |
Features