Free shipping

Schneider Electric LUCA12FU Standard control unit, TeSys Ultra, 3A to 12 A, class 10, 110 to 220VDC/AC

Brand:SCHNEIDER ELECTRIC, Condition:new
$153.00

Order today and receive in 4 weeks (pay when ready):

$0.00

LUCA12FU
PREORDER
+

Description

TeSys U standard control unit to be inserted in power bases LUB12, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 5.5kW@400V. It provides full protection to motors with a rated current Ir 3-12A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).


Main

rangeTeSys
Range of ProductTeSys Ultra
product nameTeSys Ultra
device short nameLUCA
Product or Component TypeStandard control unit
Device ApplicationMotor control
Motor protection
Product Specific ApplicationBasic protection requirements for motor starters: overload and short-circuit
main function availableProtection against overload and short-circuit
Manual reset
Earth fault protection
Protection against phase failure and phase imbalance
product compatibilityPower base LUB12
Power base LUB32
Power base LUB38
Power base LUB120
Power base LUB320
Power base LUB380
Reversing contactor breaker LU2B12FU
Reversing contactor breaker LU2B32FU
Reversing contactor breaker LU2B38FU
[Ue] rated operational voltage690 V AC
network frequency40...60 Hz
load type3-phase motor self-cooled
utilisation categoryAC-41
AC-43
AC-44
motor power kW5.5 kW 400...440 V AC 50/60 Hz
5.5 kW 500 V AC 50/60 Hz
9 kW 690 V AC 50/60 Hz
rated motor current adjustment range3…12 A
thermal overload classClass 10 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2
Class 10 40…60 Hz -13…158 °F (-25…70 °C) UL 508
tripping threshold14.2 x Ir +/- 20 >#/span###
phase failure sensitivityYes
[Uc] control circuit voltage110...240 V AC
110...220 V DC

Complementary

control circuit voltage limits88...264 V AC 110...240 V in operation
88...242 V DC 110...220 V in operation
55 V AC 110...240 V drop-out
55 V DC 110...220 V drop-out
typical current consumption280 mA 110...240 V AC I maximum while closing with LUB12
280 mA 110...240 V AC I maximum while closing with LUB32
280 mA 110...240 V AC I maximum while closing with LUB38
280 mA 110...220 V DC I maximum while closing with LUB12
280 mA 110...220 V DC I maximum while closing with LUB32
280 mA 110...220 V DC I maximum while closing with LUB38
35 mA 110...240 V AC I rms sealed with LUB12
25 mA 110...240 V AC I rms sealed with LUB32
25 mA 110...240 V AC I rms sealed with LUB38
35 mA 110...220 V DC I rms sealed with LUB12
25 mA 110...220 V DC I rms sealed with LUB32
25 mA 110...220 V DC I rms sealed with LUB38
heat dissipation2 W control circuit with LUB12
3 W control circuit with LUB32
3 W control circuit with LUB38
operating time35 ms opening with LUB12 control circuit
35 ms opening with LUB32 control circuit
35 ms opening with LUB38 control circuit
50 ms closing with LUB12 control circuit
50 ms closing with LUB32 control circuit
50 ms closing with LUB38 control circuit
standardsEN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
Product CertificationsCEbr>CSA
CCC
EAC
ASEFA
ATEX
Marine
[Ui] rated insulation voltage690 V IEC 60947-6-2
600 V UL 60947-4-1
600 V CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV IEC 60947-6-2
safe separation of circuit400 V SELV between the control and auxiliary circuits IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
fixing modePlug-in front face)
Width1.77 in (45 mm)
Height2.60 in (66 mm)
Depth2.36 in (60 mm)
Net Weight0.30 lb(US) (0.135 kg)
compatibility codeLUCA

Environment>th >ambient air temperature for operation

IP degree of protectionIP20 front panel and wired terminals IEC 60947-1
IP20 other faces IEC 60947-1
IP40 front panel outside connection zone IEC 60947-1
protective treatment
-13…158 °F (-25…70 °C)
Ambient Air Temperature for Storage-40…185 °F (-40…85 °C)
operating altitude6561.68 ft (2000 m)
fire resistance1760 °F (960 °C) parts supporting live components IEC 60695-2-12
1202 °F (650 °C) IEC 60695-2-12
shock resistance10 gn power poles open IEC 60068-2-27
15 gn power poles closed IEC 60068-2-27
vibration resistance2 gn 5…300 Hz power poles open IEC 60068-2-6
4 gn 5…300 Hz power poles closed IEC 60068-2-6
resistance to electrostatic discharge8 kV 3 in open air IEC 61000-4-2
8 kV 4 on contact IEC 61000-4-2
non-dissipating shock wave1 kV serial mode IEC 60947-6-2
2 kV common mode IEC 60947-6-2
resistance to radiated fields9.14 V/m (10 V/m) 3 IEC 61000-4-3
resistance to fast transients2 kV 3 serial link IEC 61000-4-4
4 kV 4 all circuits except for serial link IEC 61000-4-4
immunity to radioelectric fields10 V IEC 61000-4-6
immunity to microbreaks3 ms
immunity to voltage dips70 % / 500 ms IEC 61000-4-11

Ordering and shipping details

Category22397-TESYS U - CNTRL MOD(LUCA,LUCD)
Discount ScheduleI11
GTIN3389110364033
ReturnabilityYes
Country of originFR

Packing Units

Unit Type of Package 1PCE
Package 1 Length3.15 in (8.0 cm)
Number of Units in Package 11
Package 2 Width11.81 in (30.0 cm)
Package 2 Height5.91 in (15.0 cm)
Package 2 Weight7.05 lb(US) (3.2 kg)
Package 1 Width2.01 in (5.1 cm)
Package 1 Height4.02 in (10.2 cm)
Package 1 Weight4.41 oz (125.0 g)
Number of Units in Package 223
Unit Type of Package 2S02
Package 2 Length15.75 in (40.0 cm)

Contractual warranty

Warranty18 months

Show more specifications

arrow2_down

Sustainability

Green premium brand logo
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn more

arrow2_left Well-being performance

Mercury free

information_stroke

notification_ok

RoHS exemption information

information_stroke

Yes

PVC free

information_stroke

notification_ok

Halogen free plastic parts product

information_stroke

notification_ok

REACh Regulation

information_stroke

REACh Declaration

EU RoHS Directive

information_stroke

Compliant

EU RoHS Declaration

China RoHS Regulation

information_stroke

China RoHS declaration

Product out of China RoHS scope. Substance declaration for your information.

Environmental Disclosure

information_stroke

Product Environmental Profile

WEEE

information_stroke

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Circularity Profile

information_stroke

End of Life Information




Attachments

datasheet (TeSys_Ultra_Combination_Motor_Starter_LUCA12FU.pdf, 122 Kb) [Download]

MANUFACTURERS

Price history Price history