Description
Range of product | Telemecanique Emergency stop rope pull switches XY2C |
---|---|
Product or component type | Latching emergency stop rope pull switch |
Device short name | XY2CH |
Housing colour | Red RAL 3000 |
Overvoltage category | Class I conforming to EN/IEC 61140 Class I conforming to NF C 20-030 |
Complementary
Local signalling | Without pilot light |
---|---|
Number of cables | 1 |
Trigger cable maximum length | 30 m |
Body material | Zamak |
Cover material | Stainless steel |
Reset | By mushroom head push-button |
Contacts type and composition | 1 NC + 1 NO |
Contact operation | Slow-break |
Trigger cable anchor point | RH or LH side |
Connections - terminals | Screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
Tightening torque | 0.8…1.2 N.m |
Cable entry number | 3 tapped entry for Pg 13.5 cable gland |
Safety level | Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
Safety reliability data | B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear |
Marking | CE |
Mechanical durability | 800000 cycles |
Distance between cable supports | 5 m |
[Ie] rated operational current | 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current | 10 A |
[Ui] rated insulation voltage | 500 V (pollution degree 3) conforming to EN/IEC 60947-1 300 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-1 |
Positive opening | With conforming to EN/IEC 60947-5-1 |
Maximum resistance across terminals | 25 MOhm conforming to EN/IEC 60255-7 category 3 25 MOhm conforming to NF C 93-050 method A |
Short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60269 |
Terminals description ISO n°1 | (13-14)NO (21-22)NC |
Net weight | 0.9 kg |
Compatibility code | XY2CH |
Environment
Standards | EN/IEC 60204-1 Work equipment directive 2009/104/EC EN/IEC 60947-5-1 EN/ISO 13850 Machinery directive 2006/42/EC EN/IEC 60947-5-5 |
---|---|
Product certifications | CCC category NISD emergency stop devices UL |
Protective treatment | TC |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -40…70 °C |
Vibration resistance | 10 gn (f= 10…150 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance | 50 gn 11 ms conforming to EN/IEC 60068-2-27 |
IP degree of protection | IP65 conforming to IEC 60529 |
Contractual warranty
Warranty | 18 months |
---|
MANUFACTURERS
Price history
As soon as the price of the products decreases, you will immediately know about it.
The price has not changed yet. We will show it on this chart once it changes