Sick VL180-2P42431 | P/N 6041819 Cylindrical photoelectric sensors V180-2

Brand:SICK, Condition:new
$47.00
VL180-2P42431
2 in stock (more units ~3 weeks)
+

Description

  • Sensor/ detection principlePhotoelectric retro-reflective sensor, Dual lens
    Dimensions (W x H x D)18 mm x 18 mm x 70.2 mm
    Housing design (light emission)Cylindrical
    Housing length70.2 mm
    >td >M18 x 1
    Optical axisAxial
    Sensing range max.0.05 m ... 7 m 1)
    Sensing range0.05 m ... 6 m 1)
    Type of lightVisible red light
    Light sourceLED 2)
    Light spot size (distance)Ø 400 mm (6 m)
    Angle of dispersionApprox. 4.5°
    Wave length645 nm
    AdjustmentPotentiometer, 270° (Sensitivity)
    • 1) Reflector PL80A.
    • 2) Average service life: 100,000 h at TU = +25 °C.
  • Mechanics/electronics
    Supply voltage10 V DC ... 30 V DC 1)
    Ripple± 10 % 2)
    Current consumption30 3)
    Switching outputPNP 4)
    Switching modeLight/dark switching 4)
    Switching mode selectorSelectable via L/D control cable
    Signal voltage PNP HIGH/LOWApprox. VS – 1.8 V / 0 V
    Output current Imax.≤ 100 mA
    Response time≤ 0.5 ms 5)
    Switching frequency1,000 Hz 6)
    Connection typeMale connector M12, 4-pin
    Circuit protection

    A 7)

    B 8)

    D 9)

    Protection classIII
    Weight47 g
    Polarisation filter
    Housing materialMetal, Nickel-plated brass and PC
    Optics materialPlastic, PMMA
    Enclosure ratingIP67
    Items suppliedReflector P250, fastening nuts (2 x)
    Ambient operating temperature–25 °C ... +55 °C
    Ambient storage temperature–40 °C ... +70 °C
    UL File No.NRKH2.E300503 & NRKH8.E300503
    • 1) Limit values when operated in short-circuit protected network: max. 8 A.
    • 2) May not exceed or fall below Uv tolerances.
    • 3) Without load.
    • 4) Control wire open: dark switching D.ON.
    • 5) Signal transit time with resistive load.
    • 6) With light/dark ratio 1:1.
    • 7) A = VS connections reverse-polarity protected.
    • 8) B = inputs and output reverse-polarity protected.
    • 9) D = outputs overcurrent and short-circuit protected.
  • Safety-related parameters
    MTTFD2,006 years
    DCavg0>#/td###
  • Classifications
    ECl@ss 5.027270902
    ECl@ss 5.1.427270902
    ECl@ss 6.027270902
    ECl@ss 6.227270902
    ECl@ss 7.027270902
    ECl@ss 8.027270902
    ECl@ss 8.127270902
    ECl@ss 9.027270902
    ECl@ss 10.027270902
    ECl@ss 11.027270902
    ETIM 5.0EC002717
    ETIM 6.0EC002717
    ETIM 7.0EC002717
    UNSPSC 16.090139121528

MANUFACTURERS