Sick WL11G-2B2531 | 1041390 Photoelectric retro-reflective sensor

SICK, Condition:NEW, ORIGINAL PACKAGING, Source:MANUFACTURER'S NETWORK
$175.00
WL11G-2B2531
1 in stock (more units ~3 weeks)
+

Description

Features

Functional principlePhotoelectric retro-reflective sensor
Functional principle detailAutocollimation
Dimensions (W x H x D)15.6 mm x 48.5 mm x 42 mm
Housing design (light emission)Rectangular
Sensing range max.0 m ... 4 m 1)
Sensing range0 m ... 4 m 1)
FocusApprox. 1.5°
Type of lightVisible red light
Light sourceLED 2)
Light spot size (distance)Ø 25 mm (1.5 m)
Angle of dispersionApprox. 1.5°
Wave length640 nm
AdjustmentPotentiometer, 11 turns
Special featureDetecting transparent objects
Special applicationsDetecting transparent objects

1) Reflector PL80A.

2) Average service life: 100,000 h at TU = +25 °C.


Mechanics/electronic

Supply voltage10 V DC ... 30 V DC 1)
Ripple< 5 Vpp 2)
Current consumption30 mA 3)
Switching output

PNP 4)

NPN 5)

Switching modeLight/dark switching 4) 5)
Switching mode selectorSelectable via L/D control cable
Signal voltage PNP HIGH/LOWUv - 3 V / approx. 0 V
Signal voltage NPN HIGH/LOWApprox. Uv / < 3 V
Output current Imax.≤ 100 mA
Response time≤ 330 µs 6)
Switching frequency1,500 Hz 7)
Attenuation along light beam> 8 >#/td###
Connection typeMale connector M12, 5-pin
Circuit protection

8)

9)

10)

Protection classII
Weight120 g
Polarisation filter
Housing materialPlastic, ABS
Optics materialPlastic, PMMA
Enclosure rating

IP66

IP67

IP69K

Special featureDetecting transparent objects
Ambient operating temperature–30 °C ... +60 °C
Ambient temperature, storage–40 °C ... +75 °C
UL File No.NRKH.E181493 & NRKH7.E181493

1) Limit values when operated in short-circuit protected network: max. 8 A.

2) May not exceed or fall below Uvtolerances.

3) Without load.

4) 0 V or not connected, light switching.

5) Uv, dark switching.

6) Signal transit time with resistive load.

7) With light/dark ratio 1:1.

8) A = VSconnections reverse-polarity protected.

9) C = interference suppression.

10) D = outputs overcurrent and short-circuit protected.


MANUFACTURERS