Description
Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) / Inverter - USA region - Yaskawa (A1000 series) - Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac / 415Vac / 440Vac) - Rated active power 150HP (Normal duty) - Rated output current 208A (Normal duty) - frequency (output) 0.01-400Hz - IP00 - with RS-422 + RS-485 communication capablilty - Wall mounting - Forced ventilation (Fan-cooling) (Standard heatsink fins)- with Integrated DC choke - 3-phase 480V class
Specifications
Primary brand
Yaskawa
Main function
Variable Speed/Frequency Drive (VSD/VFD) / Inverter
Product series / family name
A1000 series
Network frequency
(output) 0.01-400 Hz
(input) 50/60 Hz
Functions
Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) / Inverter - USA region
Droop Control
Speed/torque Control Switching
Feed Forward Control
Zero servo function
Speed search
Overtorque detection
Undertorque detection
Torque limit
17-step speed
Acceleration/Deceleration time switch
S-curve accel/decel
3-wire sequence
Auto-tuning
Dwell
Cooling fan on/off switch
Slip compensation
Torque compensation
Frequency jump
Upper/lower limits for frequency reference
DC injection braking at start and stop
Overexcitation braking
High slip braking
PID control
Energy saving control
Fault restart
Application presets
Backup
Online tuning
KEB
Overexcitation deceleration
Inertia (ASR) tuning
High Frequency Injection
Supply voltage (AC)
380Vac-480Vac (400Vac / 415Vac / 440Vac)
Display
LED 5-digit display
Type of network
3-phase input (3P)
Rated current
208A (Normal duty)
180A (heavy duty)
120% / 60s (Normal duty) or 150% / 60s (heavy duty) overload current rating
Rated power (HP)
150HP (Normal duty)
150HP (heavy duty)
Protection functions
Motor overheat
Overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss ride-thru
Overheat
Ground fault
Protection settings
(Overcurrent) output current exceeds 200% of heavy duty rating
(Overload) 120% of rated output current; normal duty
(Overload) 150% of rated output current; heavy duty
Communication protocol
RS-422
RS-485
Mounting mode
Wall mounting
Digital inputs
1 x digital input (24Vdc; Sink/Source) (S1 - Forward / Stop)
1 x digital input (24Vdc; Sink/Source) (S2 - Reverse / Stop)
1 x digital input (24Vdc; Sink/Source) (S3 - External fault)
1 x digital input (24Vdc; Sink/Source) (S4 - Fault reset)
1 x digital input (24Vdc; Sink/Source) (S5 - Multi-step speed 1)
1 x digital input (24Vdc; Sink/Source) (S6 - Multi-step speed 2)
1 x digital input (24Vdc; Sink/Source) (S7 - Jog speed)
1 x digital input (24Vdc; Sink/Source) (S8 - External Baseblock)
1 x digital input (Pulse train input)
Digital outputs
1 x digital output (SPDT Single Pole Double Throw contact type) (MA-MB-MC; MC-MB closed means fault)
1 x digital output (NO Normally Open contact type / Multi-function contact output) (M1-M2)
1 x digital output (NO Normally Open contact type / Multi-function contact output (Zero speed) contact) (M3-M4)
1 x digital output (NO Normally Open contact type / Multi-function (Speed agree 1) contact output) (M5-M6)
1 x digital output (multi-function pulse train) (MP)
Analog inputs
1 x analog input (-10...+10Vdc / 20kΩ) (Analog Input 1 - Frequency reference bias)
1 x analog input (0-20mA / 4-20mA / -10...+10Vdc / 250Ω) (Analog Input 2 - Frequency reference bias)
1 x analog input (-10...+10Vdc / PTC input) (Analog input 3 - Aux. frequency reference or motor temperature)
Analog outputs
1 x analog output (4-20mA / -10...+10Vdc) (FM - to output frequency meter)
1 x analog output (4-20mA / -10...+10Vdc) (AM - to output current meter)
Degree of protection
IP00
Net Height (mm)
694 mm
Net Width (mm)
443 mm
Net Depth (mm)
324.75 mm
Ambient air temperature for storage
-20...+60 °C
Technology used in component
Forced ventilation (Fan-cooling)
Standard heatsink fins
Integrated DC choke
Rated apparent power (S)
159kVA (Normal duty)
137kVA (heavy duty)
Application type
HVAC
Fans
Pumps
Compressors
Conveyors
Machine Tools
Extruders
Punching Presses
Winders
Order code / Manufacturer SKU
CIMRAU4A0208AAA
Manufacturer product status
Commercialized
Compliant with standard(s)
UL 508C
CSA C22.2
IEC 61508
IEC 61800-5-1
MANUFACTURERS
Price history
The price has not changed yet. We will show it on this chart once it changes